Mixed Venous Blood Draw Timing
When drawing blood from a central venous catheter for mixed venous laboratory analysis, you should discard the first 5 mL of blood and draw your sample immediately after flushing the catheter to avoid heparin contamination. 1
Key Procedural Steps
For Catheters with Heparin Lock
When drawing from a catheter that contains heparin (which is standard for central venous catheters to prevent clotting):
- Flush the catheter prior to blood collection
- Discard the first 5 mL of blood to eliminate any residual heparin 1
- Draw your sample immediately after discarding this volume
- Process the sample promptly at room temperature, ideally within 1 hour of collection 1
For Adult Patients with Venous Catheters (General Protocol)
For standard venous catheter blood draws when heparin lock is present 2:
- Withdraw any heparin and saline from the arterial port following your unit's protocol
- Withdraw 10 mL of blood from the arterial port (for adults)
- Do not discard this blood if you intend to reinfuse it after sampling
- Connect a new syringe and draw the sample for laboratory measurement
- This ensures the sample won't be diluted by heparin
Critical Timing Considerations
The timing between blood collection and processing matters significantly:
- Blood should be kept at room temperature after collection
- Process as soon as possible, preferably within 1 hour 1
- If using plastic tubes (recommended over glass to avoid contact activation), draw blood directly into the tube rather than using a syringe first 1
Common Pitfalls to Avoid
Heparin Contamination
The most critical error is inadequate clearing of heparin from the catheter. Even small amounts will interfere with coagulation studies and potentially other analytes. The 5 mL discard volume is specifically designed to ensure complete removal 1.
Delayed Processing
While the question asks about "drawing up" labs, the processing timeline is equally important. Samples left unprocessed beyond 1 hour at room temperature may show altered results depending on the specific analytes being measured 1.
Infusion Interference
If the patient has active infusions running through the catheter, stop the infusion and wait at least 2-3 minutes before drawing blood 3, 4. Research shows that drawing blood immediately after stopping an infusion, or from above an infusing IV line, causes significant dilutional effects for most analytes 4.
Sample-Specific Considerations
For arterial or venous whole blood sampling (which is preferred for critically ill patients over finger-stick capillary samples), use the same discard volume approach when drawing from catheters 5.
For coagulation studies specifically, the citrate tube concentration should be 0.109 M, and centrifugation should occur at controlled room temperature to avoid cold activation 1.
Why This Matters
The 5 mL discard volume represents a balance between ensuring sample accuracy and minimizing blood waste in patients who may require frequent sampling. Insufficient discard volume leads to heparin contamination, which will falsely elevate coagulation times and potentially interfere with other laboratory measurements. Excessive discard contributes to iatrogenic anemia in critically ill patients who undergo frequent blood draws.