How do the blood‑gas partition coefficients of sevoflurane and nitrous oxide compare?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: April 15, 2026 • View editorial policy

Have a follow-up question?

Our Medical A.I. is used by practicing medical doctors at top research institutions around the world. Ask any follow up question and get world-class guideline-backed answers instantly.

Blood-Gas Partition Coefficients: Sevoflurane vs Nitrous Oxide

Sevoflurane has a blood-gas partition coefficient of approximately 0.65-0.74, while nitrous oxide has a significantly lower coefficient of approximately 0.47, making nitrous oxide substantially less soluble in blood and therefore faster in onset and offset than sevoflurane.

Specific Partition Coefficient Values

Sevoflurane

The blood-gas partition coefficient for sevoflurane has been measured across multiple studies with consistent findings:

  • 0.686 ± 0.047 in the original 1987 study 1
  • 0.74 ± 0.06 in a larger 2015 clinical population study of 120 patients 2

The 2015 study 2 found values approximately 12% higher than previously published means, suggesting that clinical uptake and elimination may occur more slowly in real-world patients than initially supposed. This study is particularly relevant as it examined a clinically diverse adult population (ASA I-III, ages 19-86 years) rather than just healthy volunteers.

Nitrous Oxide

Nitrous oxide has a blood-gas partition coefficient of approximately 0.47, making it the least soluble of commonly used inhalational agents. This extremely low solubility explains its rapid equilibration between inspired and alveolar concentrations, with FA/FI reaching 0.986 ± 0.003 at 30 minutes 3.

Clinical Implications

The 36-57% lower blood-gas partition coefficient of nitrous oxide compared to sevoflurane translates directly to faster induction and emergence times:

  • Nitrous oxide reaches near-complete alveolar equilibration (FA/FI ~0.99) within 30 minutes
  • Sevoflurane reaches only FA/FI of 0.85 at 30 minutes under similar conditions 3
  • After 5 minutes of elimination, sevoflurane FA/FA0 is 0.157 compared to slower washout with more soluble agents 3

The Second Gas Effect

When nitrous oxide and sevoflurane are used together, nitrous oxide's rapid uptake creates a concentration effect that accelerates sevoflurane uptake 4, 5:

  • Arterial sevoflurane partial pressures are 23.6% higher at 2 minutes when combined with 70% nitrous oxide 4
  • This effect is 2-3 times more powerful on arterial concentrations than on end-tidal concentrations 4
  • The combination produces significantly lower BIS scores (25.4 vs 40.7 at 5 minutes), indicating deeper anesthesia 4

Important Caveats

Patient variability: The 2015 study 2 found minimal correlation between partition coefficients and patient factors (age, gender, BMI, hemoglobin, hematocrit), with only weak trends for isoflurane. This means the coefficients are relatively stable across diverse patient populations.

Temperature dependency: All partition coefficients are measured at 37°C; hypothermia or hyperthermia will alter these values.

Clinical context: While nitrous oxide has lower blood solubility, its maximum safe concentration (typically 70%) limits its use as a sole anesthetic agent, whereas sevoflurane can be used at higher MAC multiples for deeper anesthesia.

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.