PICC Line Tip in the Innominate Vein is NOT an Appropriate Position
A PICC line tip positioned in the innominate (brachiocephalic) vein should be repositioned to the lower superior vena cava (SVC) or cavoatrial junction, as this location is associated with significantly increased risk of venous thrombosis and other complications.
Why This Position is Problematic
The innominate/brachiocephalic vein represents a suboptimal to inappropriate tip location based on multiple lines of evidence:
Thrombosis Risk
- Venous thrombosis is substantially more common when catheter tips terminate in the subclavian or innominate veins compared to the SVC or right atrium 1
- Research demonstrates that catheter tips positioned in the brachiocephalic vein or cranial superior vena cava carry a high risk of thrombosis 2
- The mechanism relates to greater vessel length exposed to the catheter, which increases thrombotic risk 1
Guideline Recommendations
The 2015 MAGIC guidelines 3 explicitly state that:
- The FDA and specialty societies recommend CVCs terminate in the lower one third of the superior vena cava or cavoatrial junction
- "Higher" positions (such as the upper one third of the SVC) were specifically not recommended
- Adjustment of the PICC when the tip is in the upper or middle one third of the superior vena cava was rated as appropriate 3
The innominate vein is anatomically proximal (higher) than even the upper SVC, making it an even less acceptable position.
Clinical Implications
Complication Rates
Studies consistently show:
- Non-central PICCs have higher complication rates (47% vs 29%) and more non-elective removals compared to centrally positioned catheters 4
- Brachiocephalic catheter positions show higher rates of infiltration and mechanical complications 5
- In one study, proper positioning was confirmed in only 44% of right-sided approaches, with the innominate vein being a common malposition site 6
What Should Be Done
The catheter must be repositioned. Options include:
- Guidewire exchange to advance the catheter to proper position (lower SVC or cavoatrial junction) 3
- Fluoroscopic repositioning in interventional radiology (100% success rate reported) 7
- Do not simply advance a migrated PICC without guidewire exchange 3
Optimal Tip Position
The target location should be:
- Lower one third of the superior vena cava (1.5-2.4 vertebral body units below the carina) 8
- Cavoatrial junction 3
- Even the right atrium is considered acceptable by contemporary guidelines (though this deviates from older recommendations) 3
Common Pitfall
Do not leave the catheter in the innominate vein simply because it is "technically functional" or because repositioning seems inconvenient. The increased thrombosis risk (with potential complications including pulmonary embolism at 5-14% incidence, DVT recurrence at 2-5%, and postphlebitic syndrome at 10-28%) 1 far outweighs the effort required for repositioning.
Left-sided PICC approaches have better success rates for proper positioning (79% vs 44%) and should be considered when feasible 6.