Is an Inferior Vena Cava (IVC) caliber of 1.3 cm with a respiratory variation greater than 50% and a right atrial (RA) pressure of 3 mmHg considered normal in a healthy 42-year-old female?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: May 14, 2025View editorial policy

Personalize

Help us tailor your experience

Which best describes you? Your choice helps us use language that's most understandable for you.

From the Guidelines

Yes, an IVC caliber of 1.3 cm with respiratory variation >50% and a right atrial pressure of 3 mmHg is considered normal in a healthy 42-year-old female. These values indicate normal central venous pressure and adequate intravascular volume status. The inferior vena cava typically measures between 1.0-2.0 cm in diameter in healthy adults, with 1.3 cm falling well within this normal range. The significant respiratory variation (>50%) suggests normal cardiac filling pressures and good volume responsiveness. A right atrial pressure of 3 mmHg is also within the normal range of 0-5 mmHg for healthy individuals, as suggested by the 2016 ESC/ERS guidelines 1.

Key Points

  • The IVC diameter of 1.3 cm is within the normal range for healthy adults.
  • The respiratory variation of >50% indicates normal cardiac filling pressures and good volume responsiveness.
  • A right atrial pressure of 3 mmHg is within the normal range of 0-5 mmHg for healthy individuals, according to the guidelines 1.
  • The collapsibility of the IVC during respiration (>50% variation) is particularly important as it indicates that the patient is not volume overloaded, which would typically present with a dilated IVC and minimal respiratory variation.

Clinical Implications

The parameters provided reflect proper cardiovascular function with normal preload conditions. The guidelines from the European Society of Cardiology (ESC) and the European Respiratory Society (ERS) support the use of echocardiography to estimate right atrial pressure (RAP) based on the diameter and respiratory variation in diameter of the inferior vena cava (IVC) 1. However, it is essential to consider the limitations of these estimates and the potential for inaccuracies in individual patients.

Recommendations

Based on the most recent and highest quality study, the 2016 ESC/ERS guidelines 1, an IVC caliber of 1.3 cm with respiratory variation >50% and a right atrial pressure of 3 mmHg is considered normal in a healthy 42-year-old female. These values should be interpreted in the context of the patient's overall clinical presentation and other diagnostic findings.

From the Research

IVC Calibre and Respiratory Variation

  • The provided studies do not directly address the normal range for IVC calibre and respiratory variation in a healthy 42-year-old female.
  • However, a study on estimating right atrial pressure on inferior vena cava ultrasound in Asian patients 2 found that the optimal IVC maximum diameter and percent collapse cut-offs to detect elevated RAP were smaller in Asian subjects than in a previously reported Western cohort.
  • Another study on IVC diameter in patients with chronic heart failure 3 found that the IVC diameter was correlated with log [NT-proBNP] and was an independent predictor of poor outcome.

Right Atrial Pressure

  • A study on estimating right atrial pressure on inferior vena cava ultrasound in Asian patients 2 found that the IVC maximum diameter cut-off for detecting RAP >10mmHg was 19mm, and the percent collapse cut-off was 30%.
  • A study on right atrial function role in tricuspid regurgitation-related systemic venous congestion 4 found that variables independently associated with eRAP >10 mmHg were EROA, RVol, and RA strain.
  • Given the RA pressure of 3 mmHg, it is considered normal, as it is below the cut-off value of 10mmHg.

Normal Range for IVC Calibre and Respiratory Variation

  • There is no direct evidence in the provided studies to confirm whether an IVC calibre of 1.3 cm with a respiratory variation >50% is considered normal in a healthy 42-year-old female.
  • However, the studies suggest that IVC diameter and respiratory variation are important indicators of right atrial pressure and cardiac function 2, 3, 4.

References

Guideline

Guideline Directed Topic Overview

Dr.Oracle Medical Advisory Board & Editors, 2025

Research

Estimation of right atrial pressure on inferior vena cava ultrasound in Asian patients.

Circulation journal : official journal of the Japanese Circulation Society, 2014

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.

Have a follow-up question?

Our Medical A.I. is used by practicing medical doctors at top research institutions around the world. Ask any follow up question and get world-class guideline-backed answers instantly.