Collection Tubes for Varicella and Hepatitis B Serology
For both varicella-zoster virus (VZV) serology and hepatitis B serology, use either a red-top tube (clot/serum) or gold/tiger-top SST (serum separator tube), or alternatively purple-top EDTA or PPT (plasma preparation tube) for plasma collection. 1
Hepatitis B Serology Collection
According to the 2018 IDSA/ASM guidelines, hepatitis B serologic testing (including HBsAg, anti-HBs, anti-HBc total, anti-HBc IgM, HBeAg, and HBeAb) can be performed on:
- Plasma: EDTA or PPT tubes, room temperature, transport within <2 hours
- Serum: Clot tube or SST, room temperature, transport within <2 hours 1
Both specimen types are equally acceptable for all hepatitis B serologic markers. The choice between serum and plasma is typically based on laboratory preference and workflow.
Varicella-Zoster Virus Serology Collection
While the provided guidelines do not explicitly detail VZV collection tubes in the same tabular format as hepatitis B, standard serologic testing for VZV IgG and IgM antibodies follows the same principles as other viral serology and uses serum or plasma specimens 2, 3. This means:
- Red-top (clot) or gold/tiger-top (SST) tubes for serum
- Purple-top (EDTA) or PPT tubes for plasma
Practical Considerations
Key Points:
- Both tests can be drawn in the same tube type, simplifying phlebotomy
- Most clinical laboratories prefer SST (serum separator tubes) for routine serologic testing due to ease of processing
- Transport specimens at room temperature within 2 hours for optimal results 1
- Do not freeze specimens before processing
Common Pitfalls to Avoid:
- Avoid hemolyzed specimens: Hemolysis can interfere with serologic assays and may require redraw
- Do not use heparinized tubes: Green-top tubes are not recommended for serologic testing as heparin can interfere with some immunoassays
- Check your specific laboratory's requirements: While guidelines provide general recommendations, individual laboratories may have specific preferences based on their testing platforms 1
Transport Time Matters:
The <2 hour transport time at room temperature is emphasized in the guidelines to maintain specimen integrity and ensure accurate results 1. Delays beyond this timeframe may affect antibody detection, particularly for IgM antibodies.