Aortic Dimension Reporting Shorthand on Echocardiography
Aortic dimensions on echocardiography reports are represented using standardized anatomic abbreviations with measurements in millimeters (mm) and Z-scores when indexed to body size, following specific measurement conventions that differ by imaging modality. 1
Standard Anatomic Landmarks and Abbreviations
The aortic dimensions are measured and reported at specific reproducible anatomic levels using the following shorthand:
Root and Proximal Aorta:
- Annulus (or AV annulus): Aortic valve annular diameter
- SOV or Sinuses of Valsalva: Maximum sinus diameter (widest measurement at mid-sinus level)
- STJ or Sinotubular junction: Diameter at the sinotubular junction
- AscAo or Ascending aorta (or Proximal ascending aorta): Diameter of the proximal ascending aorta
- AoArch or Aortic arch: Diameter at the aortic arch
Distal Segments (particularly in pediatric reports):
- IA-LCA: Innominate artery to left common carotid artery
- LCA-LSA: Left common carotid artery to left subclavian artery
- After LSA: Segment after left subclavian artery
- Isthmus: Aortic isthmus diameter
- Desc Ao or DAO: Descending aorta
- Abd Ao: Abdominal aorta 2
Critical Measurement Convention Differences
The measurement technique differs fundamentally between echocardiography and cross-sectional imaging, and this MUST be specified in the report:
For Echocardiography:
- Leading-edge to leading-edge (L-L) convention is recommended for aortic root and ascending aorta measurements 3
- Inner-edge to inner-edge (I-I) convention should be used ONLY for the aortic annulus 3, 1
- This distinction exists because established reference values and surgical thresholds were derived using L-L measurements, and switching to I-I would underestimate diameters by 2-4 mm, potentially missing patients at risk for dissection or rupture 3
For CT/MRI:
- Inner-edge to inner-edge (I-I) measurements are standard 1, 4
- Outer-edge to outer-edge should be reported when aortic wall abnormalities exist (atherosclerosis, discrete wall thickening) 1
Indexing and Reporting Format
Measurements should be reported with:
- Absolute values in millimeters (mm): The primary measurement
- Z-scores: Particularly important in pediatric populations and genetic syndromes 2, 4
- Indexed values:
Example Report Format:
Aortic Root Dimensions:
- Annulus: 24 mm (Z-score +1.2)
- SOV: 38 mm (Z-score +2.5,2.1 cm/m²)
- STJ: 32 mm
- AscAo: 35 mm
Measurement technique: L-L convention, 2D echoCritical Pitfalls to Avoid
1. Measurement Plane Errors:
- All measurements MUST be perpendicular to the axis of blood flow 4, 1, 4
- For asymmetric or oval contours, report BOTH the longest diameter AND its perpendicular diameter 1
- Incorrect oblique measurements will overestimate the annulus by measuring within the sinuses of Valsalva 3
2. Convention Confusion:
- Never mix measurement conventions - the 2-4 mm difference between L-L and I-I is clinically significant 3
- Always document which convention was used in the report 1
3. Reference Value Misapplication:
- Current guideline upper limits may need adjustment for sex, age, and race 5
- Men have larger absolute dimensions but women have larger BSA-indexed values 4, 5
- Asian populations have smaller aortic dimensions at all levels 5
4. Timing of Measurement:
- Aortic root measurements should be at end-diastole for reproducibility 3
- Use 2D echocardiography rather than M-mode, as M-mode systematically underestimates by ~2 mm due to cardiac motion 3
Essential Reporting Elements
Beyond the shorthand measurements, reports must include 4:
- Location of any abnormality
- Maximum diameter of any dilatation and length of abnormal segment
- Presence of morphologic abnormalities (even if diameters are normal)
- Comparison with prior studies when available
- For genetic syndromes: complete measurements of annulus, SOV, STJ, and ascending aorta 4
The standardization of this shorthand notation ensures clear communication between imaging specialists and referring clinicians, which is critical for surgical decision-making and preventing life-threatening complications like aortic dissection. 4, 1