What are the possible causes of a clicking sensation in the shoulder after a reverse total shoulder arthroplasty?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: June 18, 2026 • View editorial policy

Have a follow-up question?

Our Medical A.I. is used by practicing medical doctors at top research institutions around the world. Ask any follow up question and get world-class guideline-backed answers instantly.

Clicking After Reverse Total Shoulder Arthroplasty: Causes

Clicking in the shoulder after reverse total shoulder arthroplasty is most commonly caused by impingement between the humeral component and the scapular neck (scapular notching), component instability or subluxation, polyethylene wear, or hardware-related mechanical issues including glenoid baseplate micromotion.

Primary Mechanical Causes

The clicking sensation typically originates from one of several biomechanical complications specific to the reverse shoulder design:

Scapular Notching and Impingement

Scapular notching is the most frequent radiographic finding after reverse total shoulder arthroplasty and represents a primary source of mechanical clicking. This occurs when the humeral implant impinges against the inferior scapular neck during adduction movements 1. The erosive lesion that develops can create audible and palpable clicking as the components interact 2. The incidence and severity relate directly to:

  • Glenosphere size, shape, and positioning
  • Humeral neck-shaft angle inclination
  • Implant offset characteristics
  • Native scapular anatomy 2

While the clinical significance of mild notching remains debated, severe notching can lead to functional deterioration and glenoid implant loosening 2.

Component Instability and Subluxation

Glenohumeral instability represents a critical cause of clicking that requires immediate attention, as it frequently precedes frank dislocation. The ACR guidelines identify instability as one of the most common complications specific to reverse total shoulder arthroplasty 1.

Key risk factors for instability-related clicking include:

  • Male gender (82% in dislocation cohorts) 3
  • Body mass index ≥30 kg/m² (82% association) 3
  • Subscapularis deficiency or failed repair (64% of cases) 3, 4
  • Previous shoulder surgery (64% of unstable patients) 3
  • Revision arthroplasty (6.5% dislocation rate vs. 1.6% for primary) 4

A history of postoperative subluxations before confirmed dislocation carries a 19.52 odds ratio for subsequent dislocation 4, making clicking with a sensation of instability a critical warning sign.

Polyethylene Wear and Hardware Issues

Polyethylene wear between the humeral cup and glenosphere creates debris that can cause clicking sensations 1. Additionally, glenoid baseplate micromotion or early loosening produces mechanical symptoms before radiographic changes become apparent 1.

Diagnostic Approach

Begin with standard radiographs in multiple projections (AP, Grashey, scapular Y, and axillary views) to assess hardware alignment, component positioning, and scapular notching 1. The imaging algorithm should systematically evaluate:

  1. Hardware component integrity and alignment
  2. Scapular notching presence and severity (graded radiographically)
  3. Glenoid baseplate positioning and signs of loosening
  4. Humeral component position relative to glenosphere
  5. Periprosthetic bone quality

Advanced Imaging Indications

If radiographs are normal but clicking persists with concerning features:

  • CT with metal artifact reduction for detailed hardware assessment, occult loosening, or subtle scapular notching not visible on plain films 1
  • Ultrasound for soft tissue evaluation, particularly subscapularis integrity and fluid collections 5
  • MRI with metal artifact protocols when rotator cuff pathology or soft tissue abnormalities are suspected 1

Clinical Significance and Management

Clicking alone without pain, instability symptoms, or functional decline may represent benign scapular notching or normal prosthetic mechanics and can be observed. However, clicking accompanied by:

  • Pain with specific movements
  • Sensation of instability or "giving way"
  • Progressive functional decline
  • Apprehension with certain positions

...requires thorough evaluation as these suggest impending complications that may progress to dislocation, component failure, or loosening 1, 6.

Common Pitfalls

Do not dismiss clicking in high-risk patients (male, BMI >30, subscapularis deficiency, revision cases) as this population has substantially elevated dislocation risk 3, 4. The median time to dislocation is only 7 weeks postoperatively, with 45% of unstable prostheses ultimately requiring polyethylene exchange 3.

Scapular notching on radiographs does not always correlate with symptoms, but progressive notching warrants closer monitoring as it may lead to glenoid loosening over time 2, 7. SPECT/CT can differentiate symptomatic from asymptomatic notching when clinical correlation is unclear 1.

Avoid attributing all clicking to "normal postoperative changes" beyond the first 3-6 months, as complications including loosening can manifest years after surgery, with notable radiographic changes appearing at least 5 years postoperatively 1.

References

Guideline

acr appropriateness criteria® imaging after shoulder arthroplasty: 2021 update.

Journal of the American College of Radiology, 2022

Research

Scapular Notching in Reverse Total Shoulder Arthroplasty.

The Journal of the American Academy of Orthopaedic Surgeons, 2019

Research

Early dislocation after reverse total shoulder arthroplasty.

Journal of shoulder and elbow surgery, 2014

Research

Reverse Total Shoulder Arthroplasty: Preoperative and Postoperative Imaging Findings.

Radiographics : a review publication of the Radiological Society of North America, Inc, 2025

Research

Complications in reverse total shoulder arthroplasty.

The Journal of the American Academy of Orthopaedic Surgeons, 2011

Related Questions

After reverse total shoulder arthroplasty, what is the most common orientation of dislocation (anterior versus posterior)?
Can I resume hunting after a reverse total shoulder arthroplasty?
What is the minimum recommended duration of antimicrobial therapy for a deep puncture wound?
What is the appropriate 10‑day antibiotic regimen for a patient undergoing ENT follow‑up after image‑guided fine‑needle aspiration/biopsy, assuming no documented β‑lactam allergy?
A 10‑day postpartum woman presents with dysuria and a urine culture growing mixed microbiota >100,000 CFU/mL; how should this be managed?
What are the differential diagnoses for a female patient who is HLA‑B27 positive, has joint hypermobility with frequent subluxations, sacroiliac joint osseous erosions, attention‑deficit/hyperactivity disorder‑type symptoms, reactive hypertension, subclinical postural orthostatic tachycardia syndrome (POTS), hydrotic eczema, psoriasiform epidermal hyperplasia and hyperkeratosis, and multiple chemical and food sensitivities?
Which labs should I order for hepatitis B serology, measles‑mumps‑rubella (MMR) IgG titers, and quantitative tuberculosis testing?
What are the anterior strap muscles of the neck, including their names, innervation, blood supply, and primary actions?
What oral prednisone dose is recommended for treating extensor tenosynovitis pain?
What are the dosing instructions and precautions for a standard Deltasone (prednisone) dose pack in an adult?
What does concentric remodeling on echocardiography indicate and how should it be managed?

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.