Management of Laryngospasm: APL Valve Setting and Technique
When managing laryngospasm, you should apply continuous positive airway pressure (CPAP) with 100% oxygen using a reservoir bag and facemask—this means you close the APL valve sufficiently to generate positive pressure while maintaining a patent airway, not delivering intermittent breaths. 1
Understanding the Technique
The Difficult Airway Society guidelines are explicit: apply continuous positive airway pressure with 100% oxygen using a reservoir bag and facemask whilst ensuring the upper airway is patent 1. This is fundamentally different from bag-valve-mask ventilation.
What You're Actually Doing:
- Close the APL valve to a setting that generates continuous positive pressure (typically 10-20 cmH₂O, though the exact setting depends on your specific machine and the resistance you feel)
- Hold steady pressure on the bag—you're not squeezing rhythmically to deliver breaths
- You're creating a constant distending pressure that helps break the laryngospasm by maintaining positive pressure against the closed vocal cords
- Think of it as applying CPAP, not ventilating
The Practical Approach:
- Ensure a tight mask seal with proper jaw thrust/chin lift
- Close the APL valve progressively until you feel resistance and the bag becomes taut (not fully closed, but enough to build pressure)
- Hold steady pressure—don't squeeze the bag repeatedly
- The goal is continuous positive pressure, not tidal volume delivery
- Simultaneously perform Larson's manoeuvre: apply deep pressure in the 'laryngospasm notch' between the posterior mandible and mastoid process while maintaining jaw thrust 1
Critical Pitfall to Avoid
Do not attempt forceful positive-pressure ventilation (repeatedly squeezing the bag) against a closed glottis. This can:
- Cause gastric insufflation
- Increase aspiration risk
- Worsen the laryngospasm
- Lead to post-obstructive pulmonary edema if the patient generates severe negative intrathoracic pressure against the obstruction 1
Escalation Algorithm if CPAP Fails
If laryngospasm persists despite CPAP and oxygen saturation is falling 1:
- Propofol 1-2 mg/kg IV (larger doses needed for severe/complete laryngospasm)
- Suxamethonium 1 mg/kg IV for worsening hypoxia with total cord closure
- Alternative routes if no IV access: IM (2-4 mg/kg), intralingual (2-4 mg/kg), or intraosseous (1 mg/kg)
- Atropine may be needed for bradycardia
- In extremis: surgical airway
Why This Matters for Outcomes
Laryngospasm can progress to:
- Hypoxic cardiac arrest if unrelieved
- Post-obstructive pulmonary edema (occurs in >50% of cases from forceful inspiratory efforts against obstruction) 1
- Death from prolonged hypoxemia
The continuous positive pressure technique breaks the spasm by providing a constant distending force while avoiding the complications of forceful ventilation attempts. This approach directly addresses mortality and morbidity by maintaining oxygenation while the spasm resolves, rather than fighting against a closed glottis.