CTPA in Pregnant Women with Suspected Pulmonary Embolism
CTPA should NOT be the first-line imaging test in pregnant women with suspected PE and a normal chest X-ray—lung scintigraphy (V/Q scan) is strongly preferred to minimize maternal radiation exposure. However, CTPA is appropriate as the next test when the chest X-ray is abnormal or when V/Q scanning yields nondiagnostic results. 1
Algorithmic Approach to Imaging
Step 1: Initial Assessment
- If DVT signs/symptoms present: Perform bilateral lower extremity compression ultrasound first
- If positive → treat with anticoagulation
- If negative → proceed to pulmonary imaging 1
- If NO DVT signs/symptoms: Proceed directly to pulmonary vascular imaging 1
Step 2: Chest X-Ray First
Always obtain a chest X-ray as the initial radiation-based test (strong recommendation). The CXR result determines your next imaging choice and helps minimize cumulative radiation dose to the mother. 1
Step 3: Choose Imaging Based on CXR Result
If CXR is NORMAL:
- Perform lung scintigraphy (V/Q scan) rather than CTPA (strong recommendation)
- V/Q scanning delivers significantly lower maternal radiation: 0.98-1.07 mGy to breast tissue versus 10-60 mGy with CTPA 1
- Diagnostic V/Q results occur in 75-94% of cases 1
If CXR is ABNORMAL:
- Perform CTPA as the next test (weak recommendation)
- Rationale: Higher likelihood of achieving diagnostic study, faster time to diagnosis, and ability to identify alternative diagnoses 1
If V/Q Scan is NONDIAGNOSTIC:
- Proceed to CTPA rather than managing clinically (strong recommendation for CTPA over digital subtraction angiography)
- The potentially fatal consequences of missing PE justify additional testing 1
Critical Technical Considerations for CTPA in Pregnancy
Common Pitfalls Leading to Nondiagnostic Studies
Pregnancy creates unique physiological challenges that cause 35.7% of CTPA studies to be nondiagnostic using standard protocols 2—far higher than the 2.1% rate in nonpregnant women. The primary culprit is transient interruption of contrast from unopacified blood flowing from the inferior vena cava during deep inspiration. 2
Protocol Optimization
To achieve diagnostic quality CTPA in pregnancy:
- Bolus tracking: Place ROI in the superior vena cava (not pulmonary trunk) with 100 HU threshold 3
- Contrast protocol:
- Use 300 mgI/mL concentration
- Injection rate: 5-6 mL/sec
- Volume: 50 mL followed by 40 mL saline flush 3
- Breathing instructions: Avoid deep inspiration—coach patients for shallow breath hold or shallow free breathing 4, 5
- Deep inspiration increases negative intrathoracic pressure, pulling unopacified IVC blood into right heart
- Valsalva maneuver during deep inspiration can shunt contrast from right to left atrium 4
- Technical parameters:
These optimizations reduce nondiagnostic rates from 43% to 4.8% while decreasing radiation dose (DLP from 225 to 189 mGy·cm). 3
Radiation Risk Context
The lifetime relative risk of radiation-induced breast cancer from a single CTPA in a 25-year-old woman is 1.011 (1.1% increase), and for lung cancer 1.022 (2.2% increase). 1 While these risks exist, missing a PE carries immediate mortality risk, and the absolute cancer risk increase is small. The key is using the lowest-radiation approach that achieves diagnosis—hence the preference for V/Q scanning when CXR is normal.
Important Caveats
- D-dimer should NOT be used to exclude PE in pregnancy (weak recommendation)—physiologic elevation during pregnancy reduces specificity 1
- Iodinated contrast for CTPA is safe—not associated with neonatal adverse events 7
- In unstable patients or when timely V/Q scanning is unavailable, proceed directly to CTPA rather than delaying diagnosis 1
- Both CTPA and V/Q scanning have comparable negative predictive values approaching 100% when diagnostic 8
Quality Assessment
When reviewing CTPA results, the report should specify: