Type A and Type B Dialyzer Reactions

Type A dialyzer reactions are acute anaphylactoid reactions occurring within the first 30 minutes of dialysis (typically within 10 minutes), while Type B reactions are milder, delayed reactions occurring 20-60 minutes into the session with back and chest pain—though Type B reactions have largely vanished from modern practice. 1, 2, 3

Type A Reactions (Anaphylactoid)

Clinical Features

Type A reactions present with acute, severe symptoms including:

  • Dyspnea/breathlessness (most common, 64-69% of cases) 1, 4
  • Hypotension (66% of cases) 4
  • Hypoxia (44% of cases) 4
  • Bronchospasm (25%)
  • Chest pain (22%)
  • Pruritus and/or urticaria (22%)
  • Abdominal symptoms including nausea, vomiting (22%)
  • Flushing, angioedema 1, 4

Timing and Onset

  • 54% occur within the first 30 minutes of hemodialysis 1
  • Most reactions develop within the first 10 minutes of the procedure 2
  • 64% occur during the first year of dialysis 1
  • 54% require discontinuation of the dialysis session 1

Pathophysiology

The mechanisms are multifactorial and not primarily complement-mediated as previously thought 3:

  1. IgE-mediated reactions to ethylene oxide (ETO) used in sterilization—now largely preventable with adequate degassing and rinsing 2, 3

  2. Bradykinin-mediated reactions: Negatively charged dialysis membranes (particularly AN69) cause excessive bradykinin production, which is potentiated by:

    • ACE inhibitor use (inhibits bradykinin degradation)
    • Lower pH in initial dialysis stages
    • Increased plasma dilution 2, 3
  3. Membrane-specific reactions: Polyarylsulfone family membranes (polysulfone/polyethersulfone) are most commonly implicated 1, 4, 5

Laboratory Findings

  • Eosinophilia is common (74% of cases) 1
  • This finding can help distinguish true hypersensitivity reactions from other causes of intradialytic symptoms

Type B Reactions (Largely Historical)

Clinical Features

  • Mild back and chest pain
  • Occurs 20-60 minutes into dialysis session
  • This phenomenon is vanishing from modern practice 3

Likely Causes

  • May have been due to dialyzer contaminants
  • Possibly related to complement fragment release with acetate dialysate as cofactor
  • Recent well-designed studies fail to find symptom differences between unsubstituted cellulose and synthetic membranes 3

Management Algorithm

Immediate Management During Reaction

For suspected Type A reaction:

  1. Stop dialysis immediately
  2. Do NOT return blood to patient
  3. Administer symptomatic treatment:
    • Oxygen for hypoxia/dyspnea
    • Epinephrine for anaphylaxis
    • IV fluids for hypotension
    • Antihistamines and corticosteroids
  4. Document all symptoms, timing, and membrane type used

Membrane Switching Strategy

Critical caveat: Cross-reactivity between polyarylsulfone membranes is extremely high (~85%) 4

Do NOT attempt trial-and-error rechallenge with similar membranes—this can be harmful 4

Recommended switching protocol:

  1. First-line alternative: Cellulose triacetate (used successfully in 78% of cases) 1, 4

  2. Other safe alternatives:

    • Polyacrylonitrile (PAN)
    • Polymethylmethacrylate (PMMA)
    • Substituted cellulose 4
  3. Avoid switching between different polyarylsulfone membranes (polysulfone to polyethersulfone or vice versa) due to high cross-reactivity 4

Prevention Strategies

For bradykinin-mediated reactions:

  • Discontinue ACE inhibitors if patient is on negatively charged membranes 2, 3
  • Use bicarbonate solution for dialyzer rinsing before hemodialysis 2
  • Consider membranes with modified surface to reduce negative charge

For all patients:

  • Ensure adequate dialyzer rinsing before use to remove ETO and manufacturing residuals 2
  • Consider "preprocessing" dialyzers before first use 6
  • Avoid steam-sterilized dialyzers if patient has history of reactions 4

Important Clinical Pitfalls

  1. The classification into Type A and B may complicate diagnosis and its true clinical utility is questionable in modern practice 5

  2. Polysulfone is most frequently reported not because it's more allergenic, but because it's the most commonly used membrane 5

  3. Incidence has remained stable at approximately 2.37% despite perception of increased frequency—the apparent increase is due to better reporting and recognition 1, 5

  4. Complement activation does NOT cause Type A reactions despite historical teaching—this theory has been abandoned 2, 3

  5. Rechallenge can be life-threatening—intentional and accidental rechallenges with the same membrane class have caused immediate symptom recurrence 4, 7

References

Research

Incidence of Hypersensitivity Reactions During Hemodialysis.

Kidney & blood pressure research, 2018

Research

[Acute adverse effects of dialysis].

Vnitrni lekarstvi, 2003

Research

Adverse effects of dialyzers manifesting during the dialysis session.

Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association, 1994

Guideline

clinical practice guidelines for hemodialysis adequacy, update 2006.

American Journal of Kidney Diseases, 2006

Research

Dialysis-associated allergic reactions during continuous renal replacement therapy and hemodialysis: A case report.

Hemodialysis international. International Symposium on Home Hemodialysis, 2020

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.