What are all the laboratory tests used to assess fetal lung maturity?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: August 10, 2026 • View editorial policy

Have a follow-up question?

Our Medical A.I. is used by practicing medical doctors at top research institutions around the world. Ask any follow up question and get world-class guideline-backed answers instantly.

Tests for Fetal Lung Maturity

The primary laboratory tests historically used to assess fetal lung maturity include lecithin/sphingomyelin (L/S) ratio, phosphatidylglycerol (PG), lamellar body count (LBC), and surfactant/albumin ratio, though current clinical practice has largely moved away from routine fetal lung maturity testing in favor of gestational age-based decision making.

Historical Laboratory Tests

The following tests were developed to measure surfactant concentrations in amniotic fluid obtained via amniocentesis:

Biochemical Tests

  • Lecithin/Sphingomyelin (L/S) Ratio: Measures the ratio of these two phospholipids; a ratio ≥2.0 traditionally indicated lung maturity 1, 2, 3
  • Phosphatidylglycerol (PG): Presence indicates lung maturity; absence suggests immaturity 1, 2, 3
  • Surfactant/Albumin Ratio (TDx FLM II): Was the most frequently used test but is no longer available as of December 2011 1, 4
  • Disaturated Lecithin: Measures the active component of surfactant 5

Physical Tests

  • Lamellar Body Count (LBC): Counts surfactant-containing particles; values ≥50,000/μL suggest maturity 1, 4, 3
  • Shake Test (Foam Stability Index): Simple bedside test measuring surfactant's ability to generate stable foam 2, 6
  • Tap Test: Bedside alternative with high sensitivity (96-100%) and specificity (100% at 5-10 minutes) 6

Advanced Techniques

  • Fluorescence Polarization: Rapid automated test that was widely used 2
  • Quantitative Ultrasound (quantusFLM): Non-invasive technique analyzing fetal lung texture via ultrasound and machine learning 7

Current Clinical Reality

Fetal lung maturity testing has essentially reached the end of clinical utility 5, 8. Here's why:

The Paradigm Shift

The 2019 ACOG guidelines state that FLM testing no longer has clinical utility 5. This represents a fundamental change because:

  • Gestational age is the strongest predictor of neonatal respiratory outcomes, not biochemical test results 8
  • Demonstration of mature FLM test results does not improve neonatal outcomes 8
  • Test volumes have declined precipitously—many reference laboratories discontinued FLM testing between 2016-2019 due to extremely low demand 5
  • The shift toward managed care and evidence-based practice revealed these tests were not cost-effective 3

When Corticosteroids Replace Testing

Current guidelines emphasize antenatal corticosteroid administration rather than FLM testing:

  • Administer corticosteroids between 24+0 and 34+0 weeks when preterm delivery is anticipated 9
  • May be given up to 38+0 weeks for elective cesarean section 9
  • For vasa praevia specifically, give corticosteroids from 32 weeks due to increased preterm delivery risk 10
  • Multiple courses are not recommended 9

Practical Algorithm for Modern Practice

If considering delivery before 39 weeks:

  1. Use gestational age as primary determinant, not FLM testing
  2. Administer corticosteroids if delivery anticipated between 24-34 weeks
  3. Avoid amniocentesis for FLM testing—the invasive procedure carries miscarriage risk without improving outcomes 7
  4. Base timing decisions on maternal/fetal indications, not biochemical maturity markers

Common Pitfall to Avoid

Do not order FLM testing to justify early delivery decisions. The tests were designed to predict respiratory distress syndrome, but their positive predictive value for lung maturity (56-67% for most tests) is poor compared to simply using gestational age 6. The negative predictive value (ruling out immaturity) was better, but this clinical question is now addressed by administering corticosteroids rather than testing.

Clinical laboratory directors should meet with obstetrics providers to discontinue any remaining FLM testing services 5, as these tests represent outdated practice that does not align with current evidence-based guidelines prioritizing gestational age and prophylactic corticosteroid administration.

References

Research

Biomarker tests for fetal lung maturity.

Biomarkers in medicine, 2010

Research

Comparison of four methods (L/S ratio, TDx FLM, lamellar bodies, PG) for fetal lung maturity using meta-analysis.

Clinical laboratory management review : official publication of the Clinical Laboratory Management Association, 1996

Research

Clinical and laboratory trends in fetal lung maturity testing.

Clinica chimica acta; international journal of clinical chemistry, 2010

Research

End of the line for fetal lung maturity testing.

Clinical biochemistry, 2019

Research

A comparison of three tests for determining fetal pulmonary maturity.

International journal of gynaecology and obstetrics: the official organ of the International Federation of Gynaecology and Obstetrics, 1995

Research

Fetal lung maturity testing: the end of an era.

Biomarkers in medicine, 2014

Guideline

vasa praevia: diagnosis and management: green-top guideline no. 27b.

BJOG : an international journal of obstetrics and gynaecology, 2019

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.