How can I locate mediastinal lymph node stations 4R and 4L using endobronchial ultrasound (EBUS)?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: August 18, 2026 • View editorial policy

Have a follow-up question?

Our Medical A.I. is used by practicing medical doctors at top research institutions around the world. Ask any follow up question and get world-class guideline-backed answers instantly.

Locating Stations 4R and 4L by EBUS

Both station 4R (right paratracheal) and 4L (left paratracheal) lymph nodes are accessible via EBUS-TBNA from the trachea, with 4R typically easier to visualize and sample than 4L, which often requires balloon assistance due to its more challenging angle. 1

Anatomical Access and Positioning

Station 4R (Right Paratracheal)

  • Located immediately adjacent to the right lateral tracheal wall
  • Accessed by positioning the EBUS scope in the trachea with the transducer oriented toward the right side
  • Generally straightforward to visualize and sample via the endobronchial approach
  • Part of the core stations (2L, 2R, 4L, 4R, and 7) that are reliably accessible by EBUS-TBNA 1

Station 4L (Left Paratracheal)

  • Located along the left lateral tracheal wall
  • Accessed from the trachea with the transducer oriented toward the left side
  • More technically challenging than 4R due to the slightly difficult angle 2
  • Requires careful scope manipulation to achieve optimal contact with the tracheal wall

Technical Considerations for Optimal Sampling

Balloon Use

Balloons are commonly used and recommended when targeting paratracheal stations 4R and 4L 2. The saline-filled balloon:

  • Overcomes poor contact between the ultrasound probe and bronchial wall
  • Enhances image acquisition, particularly important for the challenging 4L angle
  • Provides better acoustic coupling for clearer visualization
  • Particularly helpful for station 4L given its more difficult anatomical position

Key Practical Points

  • Station 4L is accessible by both EBUS-TBNA (from the airway) and EUS-B-FNA (from the esophagus), providing alternative sampling routes if one approach is difficult 1
  • Station 4R is primarily accessed via EBUS-TBNA; EUS access to 4R is difficult because the trachea lies between the esophageal transducer and the lymph node 1
  • When performing comprehensive mediastinal staging, both stations should be evaluated as part of systematic nodal mapping 3

Distinguishing 4L from Adjacent Stations

Station 4L must be differentiated from stations 5 and 6 (aortopulmonary window nodes), which are located more inferiorly and laterally 4. Understanding the ultrasonic anatomical relationships is crucial for accurate station identification during EBUS procedures.

Common Pitfalls

  • Inadequate balloon use for station 4L: Failure to use a balloon when sampling 4L may result in suboptimal imaging and reduced diagnostic yield
  • Latex allergy: Balloons are latex-based and cannot be used in patients with latex allergies 2
  • Misidentification of station 4L: Can be confused with stations 5 or 6 if anatomical landmarks are not carefully assessed 4
  • Incomplete sampling: In staging procedures, both 4R and 4L should be evaluated when indicated, not just the side ipsilateral to the tumor

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.