How to Document Visual Acuity in a Clinical Record
Visual acuity should be documented by recording measurements for each eye separately, specifying the testing distance (typically 20 feet/6 meters for distance, 14 inches/36 centimeters for near), the type of chart used, whether correction was worn, and the actual power of any current correction. 1, 2
Essential Documentation Elements
Distance Visual Acuity
- Measure each eye separately at 20 feet (6 meters) in a dimly lit room using high-contrast character charts 2
- Record the power of current correction being worn during testing 1, 2
- Document whether testing was performed:
- With current correction (corrected visual acuity)
- Without correction (uncorrected visual acuity)
- With pinhole (if applicable)
Near Visual Acuity
- Measure at specified working distance (typically 14 inches or 36 centimeters) 2
- Use well-lit reading card with high-contrast characters 2
- Test each eye separately before any cycloplegia 2
Critical Documentation Components
Specify the chart type used - this is frequently omitted but essential for reproducibility 3, 4, 5:
- Snellen chart
- ETDRS (Early Treatment Diabetic Retinopathy Study) chart
- LogMAR chart
- Other standardized charts
Format for Recording Results
Express visual acuity consistently:
- Standard notation: 20/20/40, etc. (or 6/6/12 in metric)
- LogMAR notation: 0.0.3, etc. (increasingly preferred for research and clinical trials)
- Avoid decimal Snellen notation (e.g., 0.5) as this creates confusion with logMAR scoring 4
Complete Documentation Example:
- Right eye: 20/40 with current correction (-2.00 sphere), tested at 20 feet using Snellen chart
- Left eye: 20/30 with current correction (-1.50 -0.75 x 180), tested at 20 feet using Snellen chart
Common Pitfalls to Avoid
- Failing to specify testing conditions - over 40% of published studies don't identify the chart used 4, 5
- Not recording the power of current correction - this is essential for future comparisons 1, 6
- Converting between notations without documentation - only 10% of studies that convert Snellen to logMAR explicitly state this 4
- Inadequate detail for replication - most studies lack sufficient procedural detail 3, 5
Additional Considerations for Special Circumstances
High Refractive Errors
Cycloplegic Refraction
When performed, document:
- Agent used (tropicamide vs. cyclopentolate) 2
- Timing of measurement relative to instillation
- Whether postcycloplegic refraction was needed 2
Presbyopic Patients
Legal and Quality Considerations
Document all examination elements performed - recording only abnormal findings may leave no way to verify what tests were actually done 7. The clinical record should reflect every aspect of the patient encounter, as inadequate documentation significantly hampers medicolegal defense 7.
For electronic health records, structured textual descriptions are now standard, though they differ qualitatively from traditional hand-drawn sketches used in paper records 8. EHR systems typically provide more complete documentation of examination elements but may lack the graphical representations that paper notes traditionally included 8.