How can I access and use the FRAX (Fracture Risk Assessment Tool) calculator for a patient with age, sex, weight, height, lumbar T‑score –2.2, prior fragility fracture, bisphosphonate use, smoking, alcohol intake, glucocorticoid exposure, rheumatoid arthritis, and estimated glomerular filtration rate (eGFR) >35 mL/min?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: September 21, 2026 • View editorial policy

Have a follow-up question?

Our Medical A.I. is used by practicing medical doctors at top research institutions around the world. Ask any follow up question and get world-class guideline-backed answers instantly.

FRAX Calculator Access and Usage

Access the FRAX calculator online at www.shef.ac.uk/FRAX or https://www.shef.ac.uk/FRAX/tool.jsp 1, 2, 1, 2, 3. This is a free, web-based tool developed by the WHO Sheffield Collaborating Centre that calculates 10-year fracture probability using easily obtainable clinical information.

How to Use FRAX for Your Patient

Required Inputs

Enter the following information into the online calculator 1, 4:

Mandatory fields:

  • Age (40-90 years)
  • Sex
  • Weight and height (to calculate BMI)

Clinical risk factors (yes/no):

  • Prior fragility fracture (after age 50)
  • Parental history of hip fracture
  • Current smoking status
  • Glucocorticoid use (≥5 mg prednisone daily for ≥3 months)
  • Rheumatoid arthritis
  • Secondary osteoporosis (other causes)
  • Alcohol intake (≥3 units/day)

Optional but recommended:

  • Femoral neck BMD (enhances prediction accuracy) 4, 5

Important Note About Your Patient's Data

For the lumbar spine T-score of -2.2: FRAX uses femoral neck BMD, not lumbar spine values 1. You'll need the femoral neck measurement if available. FRAX can still calculate risk without any BMD input, though accuracy is reduced 4, 5.

For bisphosphonate use: FRAX is validated only for untreated patients 6. If your patient is currently on bisphosphonates, FRAX may not accurately reflect their current fracture risk.

For eGFR >35 mL/min: This doesn't directly enter into FRAX but may qualify as "secondary osteoporosis" if causing bone disease 1.

Glucocorticoid Dose Adjustment

Critical adjustment needed 2: Standard FRAX assumes prednisone 2.5-7.5 mg/day. If your patient takes >7.5 mg/day:

  • Multiply the major osteoporotic fracture risk by 1.15
  • Multiply the hip fracture risk by 1.2

For example: If FRAX shows 10% major fracture risk and 2% hip fracture risk with >7.5 mg/day prednisone, adjust to 11.5% and 2.4% respectively 2.

Interpreting Results

FRAX provides two outputs 1, 4:

  1. 10-year probability of hip fracture
  2. 10-year probability of major osteoporotic fracture (hip, clinical spine, humerus, or forearm)

US Treatment Thresholds

Consider pharmacologic treatment if 1:

  • 10-year hip fracture risk ≥3%, OR
  • 10-year major osteoporotic fracture risk ≥20%

These thresholds apply to postmenopausal women and men ≥50 years with osteopenia (T-score -1.0 to -2.5) 1.

Critical Limitations to Recognize

FRAX underestimates risk in patients with 1:

  • Multiple prior fractures (only counts yes/no, not number)
  • Recent fractures (doesn't account for timing)
  • Lumbar spine BMD much lower than femoral neck
  • History of falls (not captured in the tool)
  • Vertebral fractures specifically

For patients with fall history: Consider using the Garvan fracture risk calculator (www.fractureriskcalculator.com) as a complementary tool, though it's based on less extensive data 1, 3.

Country-Specific Versions

Select the appropriate country version when accessing FRAX, as fracture incidence varies geographically 4, 7. The US version has race/ethnicity-specific calculators (White, Black, Asian, Hispanic), though concerns exist about their validity in creating treatment disparities 7.

Integration with DXA Software

Many DXA machines now have FRAX integrated directly into their reporting software following FDA approval, allowing automatic calculation when BMD is measured 7, 8.

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.