Percutaneous Device Closure for Secundum Atrial Septal Defect
Percutaneous device closure is the preferred treatment for secundum ASDs when anatomically suitable, indicated for patients with right atrial and right ventricular enlargement with or without symptoms. 1, 2
Indications for Closure
Class I (Definitive) Indications:
- Right atrial and RV enlargement with or without symptoms 1, 2
- Hemodynamically significant shunt (Qp:Qs ≥1.5) with evidence of RV volume overload 1
- Paradoxical embolism 1
- Documented orthodeoxia-platypnea 1
Do NOT close if:
- Severe irreversible pulmonary arterial hypertension (PAH) with no evidence of left-to-right shunt 1
- Small ASDs (<5 mm) without RV volume overload (unless paradoxical embolism present) 1
Important caveat: Older adults require evaluation for left atrial hypertension from diastolic dysfunction before closure, as ASD closure may worsen symptoms when the left atrium can no longer decompress into the right atrium 2.
Anatomic Suitability for Device Closure
Only secundum ASDs are amenable to percutaneous closure. 1, 3
Anatomic requirements:
- Defect diameter typically <38 mm 3, 4
- Adequate septal rims surrounding the defect for device stability 3
- Sufficient rims are no longer required along the entire margin—deficiencies of inferior, posterior, and superior rims can be accommodated with modern devices 3
Require surgical closure:
- Sinus venosus defects 1, 3
- Primum ASDs 1, 3
- Coronary sinus defects 1, 3
- Large septal aneurysm or multifenestrated septum (requires careful interventional cardiology consultation) 1
Device Selection
Two FDA-approved devices in the United States: 3
AMPLATZER Septal Occluder:
- Nitinol wire mesh with Dacron fabric
- Suitable for all secundum ASD subtypes
- Closes defects up to 38 mm diameter
- Self-centering with left and right atrial disks connected by waist
- Repositionable before release
- Major complication rate: 1.6%; overall complication rate: 7.2% 3
- Risk of cardiac erosion/perforation (rare but potentially fatal) 3
Gore HELEX Occluder:
- Nitinol with microporous expanded polytetrafluoroethylene
- Suitable for small-to-moderate defects (≤18 mm)
- Repositionable even after release
- Wire-frame fracture incidence 5-7% (usually clinically insignificant) 3
- No reported cardiac erosions 3
Practical consideration: Minimum weight of 15 kg offers technical advantages, though procedures can be performed in children ≥2 years 3
Procedural Steps
Imaging guidance:
- Transesophageal echocardiography (TEE) or intracardiac echocardiography is essential for guidance and assessment 3
- Recent data support pure transthoracic echocardiography guidance in select pediatric cases, eliminating radiation exposure 5
Procedural approach:
- Femoral vein access
- Balloon sizing of defect
- Device selection (typically 1-2 mm larger than stretched diameter)
- Sequential deployment under echocardiographic guidance
- Confirmation of device position across all rims with no residual shunt
- Assessment for interference with atrioventricular valves or venous structures
For multiple defects: Stage deployment carefully to avoid device entanglement; close inferior defect first, then superior 6
Antiplatelet Regimen
At time of implantation:
- Unfractionated heparin 100 U/kg (maximum 5000 U) intravenously 7
Post-procedure:
- Standard approach: Low-dose aspirin for 6 months 7
- Alternative for older children/adults: Aspirin plus clopidogrel for 3-6 months, then aspirin alone to complete 6 months 7
- Aspirin often initiated 1-several days before device implantation 7
Extended therapy: If residual shunt persists after device placement, continue thromboprophylaxis beyond 6 months due to ongoing paradoxical embolus risk 7
Follow-Up Recommendations
Immediate post-procedure:
- Clinical and echocardiographic evaluation before discharge
- Monitor for pericardial effusion/tamponade (can occur up to several weeks post-procedure) 1
Scheduled follow-up:
- 3 months to 1 year: Evaluation for device migration, erosion, or complications 1
- Serial echocardiography at 1,3,6, and 12 months to assess:
- Device position
- Residual shunting
- Thrombus formation
- Pericardial effusion
- Pulmonary artery pressure
- RV function 1
Annual follow-up required if: 1
- PAH persists
- Atrial arrhythmias develop
- RV or LV dysfunction present
- Coexisting valvular lesions
Emergency evaluation warranted for:
- Chest pain or syncope (possible device erosion) 1
- Fever, fatigue, vomiting, chest/abdominal pain (possible postpericardiotomy syndrome with tamponade) 1
Major Complications to Monitor
- Device embolization/migration (1-3% with AMPLATZER) 3
- Cardiac erosion/perforation with tamponade (rare but potentially fatal—unique to AMPLATZER) 3
- Atrioventricular block 3
- Thrombus formation 3
- Arrhythmias 3
- Air embolism 3
Critical point: Device erosion can present weeks after implantation and requires urgent evaluation 1. The HELEX device has not been associated with erosion but has higher wire-frame fracture rates 3.