Neonatal Intubation Cheat Sheet
Use videolaryngoscopy as your first-line approach for neonatal intubation, with cuffed tubes preferred over uncuffed, and always verify placement with end-tidal CO2 monitoring. 1
Equipment Selection
Endotracheal Tube Sizing
Cuffed tubes are recommended over uncuffed tubes to reduce reintubation rates without increasing complications 2, 3.
For infants <1 year:
For children 1-2 years:
Always have tubes 0.5 mm smaller and larger available 3. Body weight at intubation is the most reliable predictor of optimal tube depth 5.
Cuff Pressure Management
Monitor and maintain cuff pressure ≤20 cm H2O using a pressure gauge—clinical assessment alone results in excessive pressures 2, 3, 2.
Laryngoscope Choice
Videolaryngoscopy should be your primary technique for anticipated difficult airways or after failed direct laryngoscopy 2. Use a stylet with hyperangulated blades 1.
Contraindications to videolaryngoscopy:
- Inadequate mouth opening
- Fixed cervical flexion
- Upper airway obstruction with stridor 2
Premedication
Consider premedication for non-emergent intubations to improve success rates and reduce adverse events 6, 7:
- Analgesia: Remifentanil (superior pharmacokinetics) or morphine 7
- Sedation: Etomidate or ketamine; avoid midazolam in preterm infants due to hypotension 1, 7
- Vagolytic: Atropine to prevent bradycardia 7
- Paralytic: Succinylcholine (optimal kinetics but concerning side effects) or rocuronium (safer profile, longer duration) 7
Use actual body weight for drug dosing, not ideal weight 3.
Intubation Technique
Positioning and Preoxygenation
- Optimize head position: Neutral "sniffing" position
- Preoxygenate with FiO2 100% 2
- Use apneic oxygenation during the attempt 1
The Procedure
- Visualize the glottis first—experts spend more time locating landmarks than inserting the tube 8, 9
- Identify vocal cords and glottic opening (glottis visible in 89% of attempts, cords in only 61%) 9
- Use appropriate lift technique (not leverage) 9
- Limit attempts: Change technique or operator after each failed attempt 1
Do NOT use cricoid pressure if it interferes with ventilation or intubation speed 3, 4.
Tube Placement Verification
Use multiple methods immediately after intubation and after every patient move 3:
- End-tidal CO2 monitoring (MANDATORY): Most reliable confirmation in infants with adequate cardiac output 3, 10, 1
- Clinical assessment:
- Bilateral chest rise
- Equal breath sounds over axillae (not just anterior chest)
- Absence of gastric sounds 3
- Chest X-ray: Confirm tube tip between clavicles and ≥1 cm above carina 5
A positive CO2 reading confirms tracheal placement; absence of CO2 strongly suggests esophageal intubation 10.
Rescue Airway Management
If Intubation Fails
Supraglottic airway devices (laryngeal masks) are the recommended rescue for infants ≥34 weeks gestation and ≥2 kg 10, 11, 12:
- Effective alternative when face mask ventilation fails
- Should be considered if intubation is unsuccessful or not feasible 11, 12
Cannot Intubate, Cannot Oxygenate (CICO)
Step 1: Optimize basic airway management
- FiO2 100%
- Optimize head position with jaw thrust
- Insert oral/nasopharyngeal airway or supraglottic device
- Decompress stomach with NG tube 2
Step 2: If SpO2 >80%, consider waking the patient
- Reverse neuromuscular blockade with sugammadex 16 mg/kg if rocuronium/vecuronium used 2
Step 3: If SpO2 <80% and/or decreasing heart rate
- Call for help immediately
- Call ENT for emergency tracheostomy
- Consider rigid bronchoscopy with jet ventilation 2
CRITICAL WARNING: Cricothyrotomy approaches carry major failure/complication risk. Catheter cricothyrotomy is NOT recommended in children <8 years old 2.
Post-Intubation Management
Chest Compressions (if needed)
- Depth: Approximately 1/3 anterior-posterior chest diameter 10, 13
- Technique: Two-thumb encircling hands method (generates higher perfusion pressures) 10, 13
- Ratio: 3:1 compressions to ventilations (90 compressions, 30 breaths = ~120 events/minute) 10, 13
- Increase oxygen to 100% during compressions, then wean as heart rate recovers 13
Ventilation Parameters
For preterm infants receiving positive pressure ventilation:
- Use approximately 5 cm H2O PEEP 13
- T-piece resuscitators may reduce bronchopulmonary dysplasia compared to self-inflating bags 12
Common Pitfalls
- Relying on clinical assessment alone for cuff pressure—always use a manometer 2
- Not having backup tube sizes immediately available 3
- Continuing cricoid pressure when it impedes ventilation 3, 4
- Single confirmation method for tube placement—always use CO2 monitoring plus clinical assessment 3, 10
- Attempting cricothyrotomy in neonates—high failure rate, use supraglottic device instead 2
- Not recognizing that VL technique differs from direct laryngoscopy—spend time locating landmarks before tube insertion 9