ECG with Positive Lead I and aVL, but Negative Lead II: Left Axis Deviation
This ECG pattern indicates left axis deviation (LAD), with the frontal plane QRS axis between -30° and -90°, which requires evaluation for left anterior fascicular block (LAFB), structural heart disease, or technical error such as limb lead reversal.
Understanding the Axis
When lead I and aVL are positive but lead II is negative, the electrical axis of the heart is deviated leftward beyond -30°. According to AHA/ACCF/HRS guidelines, normal QRS axis in adults ranges from -30° to +90°, and left-axis deviation is defined as an axis beyond -30° 1.
The specific pattern you describe—with positive deflections in leads I and aVL but negative in lead II—places the axis somewhere between -30° and -90°, representing moderate to marked left-axis deviation 1.
Differential Diagnosis
1. Left Anterior Fascicular Block (Most Common Pathologic Cause)
LAFB is the most common pathologic explanation for marked LAD and should be your primary consideration. The diagnostic criteria include 1:
- Frontal plane axis between -45° and -90°
- qR pattern in lead aVL
- R-peak time in lead aVL ≥45 ms
- QRS duration <120 ms
Check the QRS duration and morphology in aVL to confirm or exclude LAFB.
2. Limb Lead Reversal (Critical Technical Error to Exclude First)
Before pursuing any clinical workup, you must exclude right arm-left arm limb lead reversal, which can mimic pathologic findings including myocardial infarction 2, 3, 4.
Key clues suggesting lead reversal:
- Markedly low voltage in lead II (due to right leg-left leg "distance") 3
- P wave negative or isoelectric in aVR 3
- Pattern doesn't fit clinical context 4
Always verify proper lead placement before interpreting any abnormal axis, as lead misplacement occurs frequently and can simulate serious pathology 2, 4.
3. Inferior Myocardial Infarction with LAFB
The combination of LAFB and inferior MI can coexist, though the LAD from LAFB may mask typical inferior MI findings 5. In patients with both conditions:
- Terminal S waves remain in leads II, III, and aVF (from the LAFB)
- Significant Q waves may be absent or minimal in inferior leads (only 25-50% show them) 5
- The diagnosis of inferior MI becomes difficult or impossible electrocardiographically when LAFB is present 5
4. High Lateral Coronary Occlusion
Recent evidence describes ST-elevation in aVL with ST-depression in inferior leads (II, III, aVF) as indicative of high diagonal or intermediate artery occlusion 6. If your patient has:
- Chest pain
- ST-elevation in aVL
- Reciprocal ST-depression in lead II
This represents acute coronary occlusion requiring emergent catheterization 6.
Clinical Approach Algorithm
- First: Verify lead placement - Repeat ECG if any suspicion of technical error
- Second: Assess QRS duration and morphology - Determine if LAFB criteria are met
- Third: Evaluate clinical context - Chest pain, cardiac risk factors, prior ECGs
- Fourth: Look for associated findings - ST changes, Q waves, conduction abnormalities
- Fifth: Consider structural causes - LVH, congenital heart disease (if pediatric patient)
Common Pitfalls
- Assuming pathology without verifying lead placement - Lead reversal is common and creates false diagnoses 2, 4
- Missing acute coronary occlusion - LAD with ST changes in aVL may indicate high lateral MI 6
- Over-diagnosing inferior MI in presence of LAFB - The LAFB pattern obscures typical inferior MI findings 5
- Ignoring age-appropriate norms - Children normally have more rightward axes; LAD criteria differ by age 1
Key Takeaway
The pattern of positive leads I and aVL with negative lead II represents left axis deviation that most commonly indicates left anterior fascicular block in adults, but you must first exclude limb lead reversal and then evaluate for acute coronary syndrome if clinically indicated.