Surgical Technique for Tension Band Wiring of Patellar Fractures
Tension band wiring remains a widely accepted technique for simple transverse patellar fractures, though recent evidence shows higher complication rates compared to plate fixation, particularly for complex fractures 1. The procedure converts tensile forces into compressive forces at the fracture site to promote healing.
Patient Positioning and Approach
- Position the patient supine with a tourniquet on the affected thigh
- Use a midline longitudinal incision or lateral parapatellar approach 2 over the patella, extending from the quadriceps tendon to the patellar tendon
- Evacuate the hematoma and irrigate the joint thoroughly
- Identify and preserve the retinacular tissues for later repair
Fracture Reduction
Modern "Tension Band Wiring First" Technique
The "tension band wiring first" technique significantly reduces operative time and X-ray exposure compared to traditional pointed clamp reduction 3. This approach involves:
- Pass the tension band wire through the quadriceps and patellar tendons before fracture reduction
- Use the wire itself to guide and maintain reduction rather than relying solely on clamps
- This technique proved faster and more reproducible than traditional pointed clamp methods 3
Traditional Reduction Method
- Use pointed reduction clamps to approximate the fracture fragments
- Achieve anatomic reduction of the articular surface (less than 2mm step-off)
- Verify reduction with direct visualization and fluoroscopy
K-Wire Insertion
Standard Parallel Configuration
- Insert two 1.6-2.0mm Kirschner wires longitudinally through the patella
- Start at the superior pole, advance through both fracture fragments
- Exit at the inferior pole
- Position wires 12-15mm apart, parallel to each other
- Advance wires to penetrate the opposite cortex for stability
Alternative Crossed Pin Configuration
Biomechanical studies demonstrate superior stability with crossed pins compared to parallel configuration 2. For this modification:
- Insert K-wires in a crossed pattern through the patella
- This increases rotational stability and resistance to cyclic loading 2
Four-Wire Modification
- Use four K-wires instead of two 4
- Allows each wire to be bent and impacted separately
- Reduces hardware prominence and improves wire capture 4
Tension Band Wire Application
Standard Figure-of-Eight Technique
Pass the tension band wire (18-gauge stainless steel or cable) as close to bone as possible to maximize mechanical advantage 2:
- Pass the first wire transversely through the quadriceps tendon approximately 1cm proximal to the superior pole
- Loop the wire around the protruding ends of the proximal K-wires
- Pass the wire transversely through the patellar tendon approximately 1cm distal to the inferior pole
- Loop around the distal K-wire ends
- Create a figure-of-eight pattern anterior to the patella
- Tighten the wire systematically while maintaining fracture reduction
- Twist the wire ends together and bury them to prevent soft tissue irritation
Modified Double-Wire Technique
A double tension cerclage wire system increases biomechanical strength and provides backup if one wire fails 5:
- Wrap double tension cerclage wires under the exposed K-wire ends
- Pass both wires through the tendons in figure-of-8 fashion
- This 4-step procedure allows early functional exercise and reduces failure risk 5
Triple-Bundle Wire Modification
The triple-bundle wire stitching technique enhances stability and prevents wire migration 6:
- Use three separate wire bundles instead of a single figure-of-eight
- Provides redundancy and distributes forces more evenly
- Demonstrated excellent outcomes at 3-month follow-up without complications 6
Final Steps
- Bend and bury K-wire ends: Cut K-wires leaving 3-5mm protruding, bend 180 degrees, and impact into bone to prevent migration
- Verify reduction: Confirm anatomic alignment with fluoroscopy in AP and lateral views
- Test extensor mechanism: Flex the knee to 90 degrees to ensure stable fixation without gapping
- Repair retinaculum: Close the medial and lateral retinacular tears with absorbable sutures
- Wound closure: Close in layers with drain placement if needed
Critical Technical Points
- Wire placement proximity: Pass wires as close to bone as possible rather than through soft tissue alone to maximize compression 2
- Adequate wire tension: Insufficient tightening leads to loss of reduction; excessive tension can cause wire breakage
- K-wire penetration: Ensure K-wires penetrate both cortices for adequate purchase
- Articular reduction: Accept no more than 2mm articular step-off to prevent post-traumatic arthritis 1
Common Pitfalls to Avoid
- Wire prominence: The most common complication requiring reoperation (up to 41% with K-wires) 7. Prevent by adequate wire burial and bending
- Wire migration: Occurs when K-wires are not adequately impacted or bent 6
- Loss of reduction: Results from inadequate wire tension or poor wire positioning
- Inferior pole fractures: Often missed on initial assessment; carefully evaluate the distal fragment 5
Postoperative Rehabilitation
Full weight-bearing in extension splint is permitted immediately with gradual passive mobilization 1:
- Weeks 1-2: Passive flexion to 30 degrees
- Weeks 3-4: Passive flexion to 60 degrees
- Weeks 5-6: Passive flexion to 90 degrees
- After 6 weeks: Unlimited flexion and active mobilization
- 3-6 months: Sport-specific training permitted 1
Early mobilization with continuous passive motion prevents joint stiffness and muscle atrophy while the micromotion promotes fracture healing 5.
Important Limitations
Tension band wiring shows high complication rates, especially in complex multifragmentary fractures, with recent studies favoring locking plate osteosynthesis for superior stability and fewer complications 1. Consider plate fixation for comminuted fractures rather than attempting tension band wiring in unsuitable fracture patterns.