Airway Clearance for Tracheostomy Patients Not on Mechanical Ventilation
For patients with a tracheostomy shield (not on mechanical ventilation), implement regular suctioning as-needed based on clinical indicators, ensure adequate humidification, remove and clean inner cannulas regularly, and apply high-flow oxygen to both the tracheostomy and face when needed. 1
Essential Bedside Equipment
Your bedside setup must include 1:
- Humidification equipment (critical to prevent secretion plugging)
- Suction with appropriate catheters
- Spare tracheostomy tubes (same size and one size smaller)
- Scissors and water-soluble lubricant
- Personal protective equipment
Airway Clearance Strategy
When to Suction
Suction only when clinically indicated, not on a scheduled basis 2:
- Visible secretions in the airway
- Audible breath sounds suggesting secretions
- Increased work of breathing
- Patient distress or desaturation
Avoid routine scheduled suctioning - this is unnecessary and increases complications 2.
How to Suction Properly
Use sterile technique during open suctioning 2:
- Suction catheter should occlude <50% of the tube lumen in adults
- Keep suction pressure below -200 mm Hg in adults
- Apply suction for maximum 15 seconds per attempt
- Use shallow suctioning unless deep suctioning is specifically needed for retained secretions 2
Preoxygenate before suctioning to prevent desaturation 2.
Critical: Inner Cannula Management
Remove the inner cannula first if secretions are suspected - this single action may resolve tube obstruction without further intervention 1. Inner cannulas significantly reduce occlusion risk when properly maintained 1.
Clean or replace inner cannulas regularly. Some designs require a dedicated inner cannula for connection to resuscitation equipment 1.
Humidification is Non-Negotiable
Patients with tracheostomy shields require continuous humidification 1. Small humidifying devices (Swedish noses/HME filters) can become blocked with secretions and must be monitored closely 1.
Common pitfall: HME filters becoming wet and blocked, which can be mistaken for patient deterioration 3. Check and replace these regularly.
Assessment of Tube Patency
When concerned about tube obstruction 1:
- Pass a soft suction catheter through the tube - it should advance easily beyond the tube tip into the trachea
- Never use rigid bougies for patency testing - they can create false passages if the tube is displaced 1
- If the suction catheter passes easily, the tube is patent
- If it won't pass, consider tube blockage or displacement
Emergency Algorithm for Deterioration
If your patient deteriorates 1:
- Call for help immediately and apply high-flow oxygen to both face and tracheostomy
- Remove inner cannula if present
- Pass suction catheter to assess patency
- If catheter won't pass and patient continues to deteriorate: Remove the tracheostomy tube
- After removal, apply oxygen to both face and stoma, reassess both airways
Critical point: A blocked or displaced tracheostomy tube offers no benefit and considerable harm. Don't hesitate to remove it in a deteriorating patient 1.
Pulmonary Rehabilitation
For non-ventilated tracheostomy patients, pulmonary rehabilitation training significantly improves outcomes 4:
- Respiratory muscle training
- Diaphragmatic mobility exercises
- Chest physiotherapy
- These interventions shorten hospital stays, improve muscle strength, and increase successful decannulation rates 4
Avoid These Mistakes
- Don't instill normal saline during suctioning - this should generally be avoided 2
- Don't attempt vigorous hand ventilation through a potentially displaced tube - this causes surgical emphysema and worsens the situation 1
- Don't obtain routine surveillance cultures - only culture when there's concern for acute lower respiratory tract infection 5
- Don't use scheduled suctioning protocols - suction only when clinically indicated 2
Communication and Monitoring
Patients with tracheostomy shields may have difficulty calling for help verbally. Ensure nurse call bells are accessible and consider communication aids 1.
Monitor for signs requiring intervention: increased secretions, respiratory distress, desaturation, or visible secretions in the tube.