How to Perform Induced Sputum Eosinophil Count
The procedure involves patients inhaling increasing concentrations of hypertonic saline solution (3%, 4%, and 5%) sequentially for 5 minutes each via an ultrasonic nebulizer after premedication with a short-acting bronchodilator. 1
Pre-Procedure Preparation
- Premedicate with a short-acting bronchodilator to prevent bronchospasm during the procedure 1
- Ensure spirometry and baseline assessment are completed beforehand
Sputum Induction Protocol
The standardized induction sequence follows these steps:
- Nebulize 3% hypertonic saline for 5 minutes
- Nebulize 4% hypertonic saline for 5 minutes
- Nebulize 5% hypertonic saline for 5 minutes
- Use an ultrasonic nebulizer for all concentrations 1
- Patient expectorates sputum after each inhalation period
Sample Processing
Critical timing requirement: Same-day processing is mandatory for cell quantification and viability 1. The processing steps are:
- Disperse expectorated sputum using a mucolytic agent (typically dithiothreitol/DTT)
- Filter through 48-μm mesh gauze to remove excess mucus 1
- Centrifuge the filtrate to produce a cytospin
- Prepare cytospin slides for differential cell counting
Cell Counting and Interpretation
- Count 400 nonsquamous cells on the cytospin to obtain differential cell count 1
- Eosinophilia threshold: ≥3% non-squamous cell eosinophil count indicates eosinophilic bronchitis, as this exceeds the 90th percentile for healthy patients (1.1%) 1
- The 2009 ATS/ERS guidelines note that >1.9% is outside the normal range 2
Important Clinical Considerations
The test is safe, valid, and repeatable for measuring airway inflammation 1, but several caveats exist:
- Requires specialized laboratory capability and trained technicians for same-day processing
- Cannot be stored like routine cytology specimens
- If sputum induction is unavailable or unsuccessful, bronchial wash fluid obtained at bronchoscopy provides similar information 1
- The test can also identify neutrophilia from viral or bacterial bronchitis, which are alternative causes of chronic cough 1
Alternative Simplified Method
A newer SSIMPLE method using formalin-fixed, paraffin-embedded (FFPE) sputum plugs has shown excellent correlation with standard DTT processing (ρ=0.9), with ≥2.6% eosinophils as the cut-off (sensitivity 85.4%, specificity 93.0%) 3. This method eliminates the same-day processing requirement but requires validation in your specific clinical setting.