Left Atrial Strain
Left atrial strain (LAS) is a quantitative measure of left atrial myocardial deformation assessed by speckle-tracking echocardiography that reflects the three phases of atrial function: reservoir (filling during ventricular systole), conduit (passive emptying during early diastole), and contraction (active emptying during late diastole). 1, 2
What It Measures
LAS captures three distinct strain components that correspond to specific atrial functions 2:
- Peak Atrial Longitudinal Strain (PALS) / Reservoir Strain (LASr): Measured at mitral valve opening, reflects the reservoir function as the atrium fills during ventricular systole
- Conduit Strain (LAScd): Calculated as the difference between PALS and late diastolic strain, represents passive emptying during early ventricular filling
- Contractile Strain (LASct) / Peak Atrial Contraction Strain (PACS): Measured just before atrial contraction (at P-wave onset), reflects active atrial contraction
Normal Values
The most recent population-based normative data from the Copenhagen City Heart Study (2021) established the following reference ranges for healthy individuals 3:
2D Speckle-Tracking Values:
- PALS (Reservoir): 39.4% (limits of normality: 23.0-67.6%)
- PACS (Contraction): 15.5% (limits of normality: 6.4-28.0%)
- LACS (Conduit): 23.7% (limits of normality: 8.8-44.8%)
3D Echocardiography Values (2024 Copenhagen data):
- LASr: 30.8% (limits of normality: 18.4-44.2%)
- LAScd: 19.1% (limits of normality: 6.8-32.0%)
- LASct: 11.7% (limits of normality: 4.3-22.2%) 4
Important caveat: Values vary significantly based on age, sex, heart rate, and body surface area 3, 5. PALS and conduit strain tend to decrease with age and are lower in males, while contractile strain increases with advancing age 3.
Critical Technical Consideration
The reference point for measurement matters substantially 2:
- QRS onset as reference: PALS ~47%, PACS ~20%, LACS ~27%
- P-wave onset as reference: PALS ~36%, PACS ~14%, LACS ~21%
The European Task Force recommends using QRS onset in atrial fibrillation (no P-wave present) and P-wave onset in sinus rhythm 2. However, this creates confusion for longitudinal follow-up in patients transitioning between rhythms. For practical standardization, using QRS onset consistently is more pragmatic 2.
Clinical Applications
Heart Failure with Preserved Ejection Fraction (HFpEF)
LAS <18% is associated with elevated LV filling pressures (PCWP ≥15 mmHg), particularly when LVEF <50% 1. This threshold helps identify increased filling pressure even when left atrial volume index (LAVI) remains normal 1.
The diagnostic algorithm for HFpEF should incorporate:
- LASr <18%: Indicates elevated filling pressures and supports HFpEF diagnosis 1
- Thresholds for diastolic dysfunction grading 1:
- LASr <35%: Separates normal from Grade 1-3 DD
- LASr <24%: Separates Grade 1 from Grade 2-3 DD
- LASr <19%: Separates Grade 3 from Grade 1-2 DD
LAS deteriorates progressively with DD severity, unlike LAVI which plateaus early 1. LAS is more sensitive than LAVI for detecting elevated filling pressures during sinus rhythm 1.
Atrial Fibrillation Risk Stratification
LA strain <30% indicates significant alteration of reservoir function and predicts poor outcomes 2. The Copenhagen study demonstrated that values below the lower limits of normality showed 93-94% specificity for future atrial fibrillation 3.
For AF prediction, the lateral wall strain is most reliable as it avoids technical challenges from the interatrial septum and pulmonary veins 2.
Heart Failure with Reduced Ejection Fraction
In the MESA study, subjects who developed heart failure had lower baseline LASr (25±11% vs. 38±16%, P<0.001) years before symptom onset 1. LASr was independently associated with incident HF beyond clinical risk factors, LV mass, and natriuretic peptides 1.
Prognostic Value
Reduced left atrial ejection fraction and LASr are independently associated with 8-year mortality in the general population, providing incremental prognostic utility beyond clinical risk factors, LV mass, and LVEF 1. Abnormal LASr correlates with dyspnea, NYHA class, and HF hospitalization 1.
Technical Limitations and Pitfalls
Measurement Challenges 2:
- Interatrial septum: Difficult to visualize, consists of fibromuscular tissue, influenced by right atrial pressure—consider analyzing lateral wall only
- LA appendage: Compromises speckle recognition in 2-chamber view
- Pulmonary veins: Roof of atrium contains transversely aligned fibers without longitudinal deformation properties
- Irregular rhythms: Cannot perform frame-stitching over consecutive cardiac cycles during atrial fibrillation
- Vendor dependency: Significant variability between software platforms
Standardization Issues
There is no universal consensus on acquisition methodology 2:
- Some studies use 4-chamber view only, others biplane or triplane
- Disagreement on whether to include atrial roof and septum
- Different software packages yield different absolute values
The European Task Force recommends focusing on lateral wall strain as the most reliable surrogate for atrial fibrosis 2, though this recommendation lacks robust technical validation 2.
Practical Implementation
For clinical use, prioritize:
- Use consistent ECG reference point (QRS onset preferred for standardization)
- Focus on lateral wall if technical quality of septum is poor
- Apply age- and sex-specific reference ranges from population studies
- Key clinical thresholds:
LAS provides earlier detection of atrial dysfunction than volume measurements alone and adds diagnostic precision when traditional diastolic function assessment yields indeterminate results 1, 6.