What is the recommended management for a thinned sigmoid plate with possible dehiscence?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: November 19, 2026 • View editorial policy

Have a follow-up question?

Our Medical A.I. is used by practicing medical doctors at top research institutions around the world. Ask any follow up question and get world-class guideline-backed answers instantly.

Management of Sigmoid Plate Thinning with Possible Dehiscence

For sigmoid sinus dehiscence causing pulsatile tinnitus, surgical resurfacing of the dehiscence is the definitive treatment, with transmastoid reconstruction using bone pate/cement and temporalis fascia achieving complete symptom resolution in >90% of cases.

Diagnostic Confirmation

Before proceeding with management, confirm the diagnosis with:

  • Temporal bone CT to visualize bony dehiscence
  • MR venography to assess venous anatomy and rule out stenosis
  • Document presence/absence of pulsatile tinnitus (the primary symptom requiring intervention)
  • Evaluate for contralateral transverse sinus stenosis (present in many cases) 1

Surgical Indications

Surgery is indicated when:

  • Patient has intolerable pulsatile tinnitus affecting quality of life
  • Radiographic confirmation of sigmoid sinus dehiscence or diverticulum
  • Conservative management has failed

Important caveat: Asymptomatic dehiscence does not require surgical intervention. The goal is symptom relief, not anatomical correction alone.

Surgical Approach: Transmastoid Resurfacing

The standard technique involves 2, 3, 4, 5:

Operative Steps:

  1. Cortical mastoidectomy to expose the sigmoid sinus
  2. Address ALL dehiscences - this is critical, including any overlying a diverticulum
  3. Resurfacing technique:
    • Cover dehiscence with autogenous bone pate
    • Apply bone cement over the bone pate
    • Use pedicled temporalis fascia for additional coverage
  4. If diverticulum is present: Close with pedicled temporalis fascia, but do not excise the diverticulum - resurfacing the dehiscence alone is sufficient 2

Key Technical Points:

  • The tailored re-roofing (TRR) technique is faster (average 77.5 minutes vs 174 minutes for traditional methods) and equally effective 3
  • Smaller incision with TRR provides favorable outcomes
  • Intraoperative microphone monitoring can confirm sound intensity reduction in real-time 2

Alternative: Endovascular Approach

For select cases, endovascular stenting via sagittal sinus approach is an option when 1:

  • Jugular bulb anatomy is unfavorable for traditional access
  • Patient prefers less invasive approach
  • Surgical expertise is available

This technique has shown safety and efficacy but requires specialized endovascular capabilities.

Expected Outcomes

High success rates are consistently reported:

  • Complete resolution of pulsatile tinnitus: >90% of cases 2, 3, 5
  • Korean Tinnitus Handicap Inventory scores drop from 55.0 to 4.0 postoperatively 3
  • Sound intensity reduction significant in 20-1000 Hz range 2

Critical Pitfalls to Avoid

  1. Missing additional dehiscences: Failure to address all dehiscences, especially those overlying diverticulum, leads to persistent symptoms 2
  2. Unnecessary diverticulum excision: Do not attempt to exclude/excise the diverticulum - this adds risk without benefit 2
  3. Overlooking contralateral stenosis: Check for transverse sinus stenosis on the opposite side, as this may contribute to pathophysiology 1
  4. Operating on asymptomatic patients: Radiographic findings alone are not an indication for surgery

Complications

Serious complications can occur but are uncommon 5:

  • Major complications reported in ~14% of cases
  • No permanent morbidity when complications are promptly recognized and treated
  • Vigilance required for early detection and management

Non-Operative Management

Not recommended for symptomatic sigmoid sinus dehiscence. Unlike the orthopedic plate exposure study 6 (which is irrelevant to this vascular/otologic condition), sigmoid sinus dehiscence causing pulsatile tinnitus requires definitive surgical correction for symptom resolution.

References

Research

Resurfacing Dehiscence(s) Without Reducing Diverticulum Effectively Silences Pulsatile Tinnitus: Novel Surgical Techniques for Diverticulum and Intraoperative Microphone Monitoring.

Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology, 2024

Research

Surgical Management of Pulsatile Tinnitus due to Sigmoid Sinus Diverticulum and Dehiscence - A Technical Note.

Indian journal of otolaryngology and head and neck surgery : official publication of the Association of Otolaryngologists of India, 2024

Research

Sinus wall reconstruction for sigmoid sinus diverticulum and dehiscence: a standardized surgical procedure for a range of radiographic findings.

Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology, 2011

Research

Management of orthopedic plate exposure: a case series evaluating advanced wound care and delayed hardware removal.

European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2026

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.