Blood Collection Tubes for Iron Studies, Lipids, and Vitamin D
For iron studies, lipids, and vitamin D testing, use serum separator tubes (SST/gold top) or plain red top tubes, following the standardized blood draw order: serum tubes should be drawn third (after blood culture and sodium citrate tubes), before any heparin or EDTA tubes.
Specific Tube Requirements
Serum Tubes (Red Top or Gold/Tiger Top SST)
All three tests—iron studies, lipid panel, and vitamin D—can be performed on serum specimens 1, 2, 1. The serum separator tubes (SST) contain clot activators and gel separators that facilitate clean separation of serum from cellular components 1.
- Iron studies: Serum is the standard specimen type
- Lipid panel: Serum is acceptable and widely used 3
- Vitamin D (25-OH vitamin D): Serum is the standard specimen type
Critical Collection Order
Following CLSI guidelines, the proper blood draw sequence is 1:
- Blood culture tubes (if needed)
- Sodium citrate tubes (light blue)
- Serum tubes (red/gold/tiger top) ← Draw these for your tests
- Heparin tubes (green)
- EDTA tubes (lavender)
- Sodium fluoride/potassium oxalate tubes (gray)
This order is crucial to prevent cross-contamination—if you draw an EDTA tube before a serum tube, EDTA carryover can interfere with coagulation and invalidate results 1.
Practical Collection Guidelines
Tube Handling
- Immediately after blood draw: Gently invert serum tubes 5 times to mix blood with clot activators (not needed for plain glass red tops) 1
- Fill tubes completely: Fill until vacuum is exhausted to maintain proper blood-to-additive ratios 1
- Clotting time: Allow 30 minutes for SST tubes or 60 minutes for plain red top tubes at room temperature before centrifugation 1
Processing Considerations
- Serum tubes can be refrigerated at 4°C for up to 2 hours if immediate centrifugation isn't possible 1
- For lipid testing specifically, both fasting and non-fasting samples are acceptable, though fasting status should be documented 3
- Serum separator tubes with delayed processing (up to 48 hours) produce comparable results to immediate processing for lipid measurements 4
Alternative: Plasma Tubes
While serum is preferred and most commonly used, EDTA plasma or heparin plasma can also be used for these tests at many laboratories 1. However:
- Plasma tubes would need to be drawn in the correct order (after serum tubes) 2
- Check with your specific laboratory, as some may have preferences
- EDTA tubes require 8-10 inversions immediately after collection 1
Common Pitfalls to Avoid
- Wrong draw order: Drawing EDTA before serum tubes causes additive contamination 1
- Insufficient mixing: Failure to invert tubes leads to microclots that can obstruct analyzers 1
- Underfilling tubes: Alters blood-to-additive ratios and affects results 1
- Hemolysis: Rough handling or improper technique causes hemolysis, which significantly interferes with iron studies and other analytes 1
Bottom line: One properly collected serum separator tube (gold/tiger top) or plain red top tube, drawn in the correct sequence, will provide adequate specimen for all three test panels.