Morning Cortisol Thresholds for Short Synacthen Test
A short Synacthen test (SST) should be performed when morning cortisol falls between approximately 140-350 nmol/L (5-12.6 μg/dL), as values below 140 nmol/L strongly suggest adrenal insufficiency and values above 350 nmol/L reliably exclude it.
Context-Specific Thresholds
The decision to perform an SST depends critically on the clinical context and the cortisol measurement method:
For Glucocorticoid-Induced Adrenal Insufficiency
The most recent 2024 joint European/Endocrine Society guideline provides the clearest framework 1:
When measured by immunoassay:
- Morning cortisol >310 nmol/L (>11.2 μg/dL): Excludes adrenal insufficiency with 98% sensitivity and 97% negative predictive value—SST not needed
- Morning cortisol <152 nmol/L (<5.5 μg/dL): Confirms adrenal insufficiency with 97% specificity and 95% positive predictive value—SST not needed
- Morning cortisol 152-310 nmol/L (5.5-11.2 μg/dL): SST required
When measured by LC-MS/MS (more accurate):
- Morning cortisol >327 nmol/L (>11.8 μg/dL): Excludes adrenal insufficiency with 98% sensitivity and 99% negative predictive value—SST not needed
- Morning cortisol <152 nmol/L (<5.5 μg/dL): Confirms adrenal insufficiency with 98% specificity and 99% positive predictive value—SST not needed
- Morning cortisol 152-327 nmol/L (5.5-11.8 μg/dL): SST required
For Primary Adrenal Insufficiency
The 2016 Endocrine Society guideline states 2:
- **Morning cortisol <140 nmol/L (<5 μg/dL)** combined with elevated ACTH (>2-fold above upper limit): Diagnosis highly likely—confirmatory SST recommended unless results are absolutely unequivocal
- Morning cortisol >350 nmol/L (>12.6 μg/dL): Normal adrenal function—SST not needed
- Morning cortisol 140-350 nmol/L (5-12.6 μg/dL): SST required
Important Caveats
Timing Matters
- These thresholds apply to morning cortisol measurements (ideally 8-9 AM) when cortisol is at its physiological peak
- Recent research suggests adjusted thresholds for samples collected after 0945 hours: cortisol >251 nmol/L can predict adequate adrenal reserve 3
Special Populations
- Pituitary pathology: Lower threshold of 240 nmol/L may be appropriate for excluding adrenal insufficiency with 95% specificity 3
- Pediatric patients ≤2 years: Use 0.125 mg Synacthen dose instead of standard 0.25 mg 4
Assay-Specific Considerations
The cortisol assay method significantly impacts thresholds:
- Immunoassays may overestimate cortisol compared to LC-MS/MS
- Always use assay-specific cutoffs when available
- Recent data suggests the traditional 18 μg/dL threshold may be too high; 15.6 μg/dL reduces false positives by 17.9% 5
Confounding Factors
Do not rely on morning cortisol alone if the patient:
- Takes cortisone, hydrocortisone, or spironolactone (omit pre-test doses) 4
- Takes estrogen-containing medications (may cause falsely elevated baseline cortisol)
- Has cortisol-binding globulin deficiency, glucocorticoid resistance, or hypersensitivity
- Has elevated plasma bilirubin or free hemoglobin (causes falsely high fluorescence measurements)
Clinical Algorithm
- Measure morning (8-9 AM) serum cortisol in patients with suspected adrenal insufficiency
- If cortisol >327-350 nmol/L (>11.8-12.6 μg/dL): Adrenal insufficiency excluded—no SST needed
- If cortisol <140-152 nmol/L (<5-5.5 μg/dL):
- For primary AI: Check ACTH; if elevated >2-fold, diagnosis highly likely
- For glucocorticoid-induced AI: Diagnosis confirmed
- Consider SST only if results will change management
- If cortisol 140-350 nmol/L (5-12.6 μg/dL): Perform SST
- In acute illness with high clinical suspicion: Do not delay treatment—draw baseline cortisol and ACTH, then start hydrocortisone immediately 2
SST Interpretation When Performed
Per FDA labeling and guidelines 4:
- Normal response requires:
- Baseline cortisol >5 μg/dL (140 nmol/L)
- 30-minute cortisol increment ≥7 μg/dL above baseline
- 30-minute cortisol >18 μg/dL (500 nmol/L)
- Measure cortisol at 30 and 60 minutes (both timepoints identify 2.7% of patients who pass only at 60 minutes) 3
By applying these thresholds, approximately 31-44% of SSTs can be safely avoided 3, 6, 7, reducing healthcare costs and patient burden while maintaining diagnostic accuracy.