How to Insert an Endotracheal Tube

Use direct laryngoscopy to visualize the vocal cords, pass the endotracheal tube through the cords into the trachea, and immediately confirm correct placement using both clinical assessment and end-tidal CO2 detection. 1

Pre-Intubation Preparation

Equipment Selection

Tube Size Selection:

  • Pediatric patients:

    • Infants <1 year: 3.5mm ID (uncuffed) or 3.0mm ID (cuffed)
    • Children 1-2 years: 4.0mm ID (uncuffed) or 3.5mm ID (cuffed)
    • Children >2 years: Use formulas 1:
      • Uncuffed: 4 + (age/4) mm
      • Cuffed: 3.5 + (age/4) mm
    • Always have tubes 0.5mm smaller and larger available 1
  • Adults: Standard 7.0-8.0mm ID tubes for most patients

Key Equipment:

  • Laryngoscope with appropriate blade
  • Suction device with adjustable regulator (-80 to -120 mm Hg for endotracheal suctioning) 1
  • End-tidal CO2 detector (capnography or colorimetry)
  • Bag-valve-mask with oxygen source
  • Stylet or bougie if needed

Patient Positioning

  • Position head in "sniffing" position with neck extension (unless contraindicated)
  • Ensure adequate lighting and access
  • Pre-oxygenate with 100% oxygen 2

Intubation Technique

Direct Laryngoscopy Approach

  1. Hold laryngoscope in left hand (if right-handed)
  2. Insert blade into right side of mouth, sweeping tongue to the left
  3. Advance blade to visualize epiglottis and vocal cords
  4. Lift laryngoscope handle upward and forward (do not rock back on teeth)
  5. Visualize vocal cords directly

Tube Insertion

If using a stylet or bougie:

  • Insert bougie first if cords are difficult to visualize
  • Advance bougie 10-15cm into trachea 2
  • Railroad tube over bougie with 360-degree clockwise rotation if resistance is met 3
  • Remove bougie after tube placement

Direct tube insertion:

  • Pass tube through right side of mouth
  • Watch tube pass through vocal cords under direct vision
  • Advance until cuff is 2-3cm past cords (typically 21cm mark at incisors for adults)
  • If resistance encountered, rotate tube 90 degrees counterclockwise (ventral tip position) for better passage 4

Critical Pitfall

Do NOT continue cricoid pressure if it interferes with ventilation or intubation ease 1. This is a Class III recommendation - meaning it may be harmful.

Immediate Confirmation (Mandatory)

You must use BOTH clinical assessment AND confirmatory devices 1. No single method is completely reliable.

Primary Confirmation Steps (perform ALL):

  1. Visualize bilateral chest rise
  2. Auscultate breath sounds bilaterally over axillae (not just anterior chest)
  3. Confirm ABSENCE of gastric sounds over epigastrium
  4. Check end-tidal CO2 detection (Class I recommendation) 1:
    • Capnography waveform or colorimetric color change confirms airway placement
    • Caveat: During cardiac arrest, absence of CO2 may reflect low pulmonary blood flow rather than misplacement - confirm with direct laryngoscopy 1
  5. Monitor pulse oximetry (note: may not decline for 3 minutes after pre-oxygenation) 1
  6. If uncertain, perform direct laryngoscopy again to visualize tube between cords 1

Secondary Confirmation:

  • Chest X-ray in hospital settings to verify midtracheal position and rule out bronchial intubation 1
  • Tube tip should be 5cm above carina

Securing and Maintenance

  1. Inflate cuff:

    • Monitor pressure with manometer
    • Keep pressure <20-25 cm H2O 1
    • Cuff pressure >20 cm H2O increases complications without benefit 5
  2. Secure tube (no single method proven superior)

  3. Maintain head in neutral position 1:

    • Neck flexion pushes tube deeper
    • Neck extension pulls tube out
  4. Reconfirm placement:

    • After securing tube
    • During any patient transport
    • Each time patient is moved 1

Troubleshooting Post-Intubation Deterioration

Use DOPE mnemonic 1:

  • Displacement of tube
  • Obstruction of tube
  • Pneumothorax
  • Equipment failure

Special Considerations

Difficult Airway Scenario

If standard laryngoscopy fails:

  • Consider videolaryngoscopy for anticipated difficult intubation 5
  • Use bougie technique with tube rotation 3
  • Have emergency front-of-neck airway (eFONA) equipment immediately available 2

Cuffed vs Uncuffed Tubes

Both are acceptable in pediatrics (Class IIa) 1. Cuffed tubes may be preferable with:

  • Poor lung compliance
  • High airway resistance
  • Large glottic air leak

The evidence shows cuffed tubes have no increased complication risk when cuff pressure is monitored 1.

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.