How to Insert an Endotracheal Tube
Use direct laryngoscopy to visualize the vocal cords, pass the endotracheal tube through the cords into the trachea, and immediately confirm correct placement using both clinical assessment and end-tidal CO2 detection. 1
Pre-Intubation Preparation
Equipment Selection
Tube Size Selection:
Pediatric patients:
Adults: Standard 7.0-8.0mm ID tubes for most patients
Key Equipment:
- Laryngoscope with appropriate blade
- Suction device with adjustable regulator (-80 to -120 mm Hg for endotracheal suctioning) 1
- End-tidal CO2 detector (capnography or colorimetry)
- Bag-valve-mask with oxygen source
- Stylet or bougie if needed
Patient Positioning
- Position head in "sniffing" position with neck extension (unless contraindicated)
- Ensure adequate lighting and access
- Pre-oxygenate with 100% oxygen 2
Intubation Technique
Direct Laryngoscopy Approach
- Hold laryngoscope in left hand (if right-handed)
- Insert blade into right side of mouth, sweeping tongue to the left
- Advance blade to visualize epiglottis and vocal cords
- Lift laryngoscope handle upward and forward (do not rock back on teeth)
- Visualize vocal cords directly
Tube Insertion
If using a stylet or bougie:
- Insert bougie first if cords are difficult to visualize
- Advance bougie 10-15cm into trachea 2
- Railroad tube over bougie with 360-degree clockwise rotation if resistance is met 3
- Remove bougie after tube placement
Direct tube insertion:
- Pass tube through right side of mouth
- Watch tube pass through vocal cords under direct vision
- Advance until cuff is 2-3cm past cords (typically 21cm mark at incisors for adults)
- If resistance encountered, rotate tube 90 degrees counterclockwise (ventral tip position) for better passage 4
Critical Pitfall
Do NOT continue cricoid pressure if it interferes with ventilation or intubation ease 1. This is a Class III recommendation - meaning it may be harmful.
Immediate Confirmation (Mandatory)
You must use BOTH clinical assessment AND confirmatory devices 1. No single method is completely reliable.
Primary Confirmation Steps (perform ALL):
- Visualize bilateral chest rise
- Auscultate breath sounds bilaterally over axillae (not just anterior chest)
- Confirm ABSENCE of gastric sounds over epigastrium
- Check end-tidal CO2 detection (Class I recommendation) 1:
- Capnography waveform or colorimetric color change confirms airway placement
- Caveat: During cardiac arrest, absence of CO2 may reflect low pulmonary blood flow rather than misplacement - confirm with direct laryngoscopy 1
- Monitor pulse oximetry (note: may not decline for 3 minutes after pre-oxygenation) 1
- If uncertain, perform direct laryngoscopy again to visualize tube between cords 1
Secondary Confirmation:
- Chest X-ray in hospital settings to verify midtracheal position and rule out bronchial intubation 1
- Tube tip should be 5cm above carina
Securing and Maintenance
Inflate cuff:
Secure tube (no single method proven superior)
Maintain head in neutral position 1:
- Neck flexion pushes tube deeper
- Neck extension pulls tube out
Reconfirm placement:
- After securing tube
- During any patient transport
- Each time patient is moved 1
Troubleshooting Post-Intubation Deterioration
Use DOPE mnemonic 1:
- Displacement of tube
- Obstruction of tube
- Pneumothorax
- Equipment failure
Special Considerations
Difficult Airway Scenario
If standard laryngoscopy fails:
- Consider videolaryngoscopy for anticipated difficult intubation 5
- Use bougie technique with tube rotation 3
- Have emergency front-of-neck airway (eFONA) equipment immediately available 2
Cuffed vs Uncuffed Tubes
Both are acceptable in pediatrics (Class IIa) 1. Cuffed tubes may be preferable with:
- Poor lung compliance
- High airway resistance
- Large glottic air leak
The evidence shows cuffed tubes have no increased complication risk when cuff pressure is monitored 1.