What is the normal reference range for plasma free metanephrine and normetanephrine?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: November 22, 2026 • View editorial policy

Have a follow-up question?

Our Medical A.I. is used by practicing medical doctors at top research institutions around the world. Ask any follow up question and get world-class guideline-backed answers instantly.

Normal Range of Plasma Free Metanephrine and Normetanephrine

Reference intervals for plasma free metanephrines must be established and interpreted based on supine positioning, with age-adjusted cutoffs for normetanephrine to optimize diagnostic accuracy. 1

Position-Specific Reference Intervals

The Endocrine Society guidelines emphasize that blood samples must be drawn after the patient has been fully recumbent (supine) for at least 30 minutes, and reference intervals should be established in this same position 1. This is critical because:

  • Upright/seated positioning increases plasma normetanephrine by up to 2-fold compared to supine values 1
  • Using seated reference intervals results in a 2.8-fold increase in false-positive results 1
  • Conversely, using seated cutoffs when patients are sampled supine leads to a 3-fold increase in false-negative results 1

Age and Gender-Adjusted Reference Ranges

Normetanephrine (Age-Dependent)

Normetanephrine increases significantly with age and requires age-stratified cutoffs 2:

  • Children (5-17 years): Upper limit 0.47 nmol/L (approximately 90 pg/mL)
  • Adults 18-30 years: Upper limit 0.47 nmol/L
  • Adults 30-40 years: Variable, increasing trend
  • Adults 40-60 years: Upper limit approximately 0.75-0.90 nmol/L
  • Adults >60 years: Upper limit 1.05 nmol/L (approximately 200 pg/mL)

Using age-adjusted cutoffs for normetanephrine improves diagnostic specificity from 88.3% to 96.0% with minimal loss in sensitivity (93.9% to 93.6%) 2.

Metanephrine (Gender-Dependent)

Metanephrine shows gender differences but minimal age variation in adults 2, 3:

  • Adult males: Upper limit approximately 0.45 nmol/L (approximately 90 pg/mL)
  • Adult females: Upper limit approximately 0.32-0.45 nmol/L (approximately 64-90 pg/mL)
  • Children: Upper limit 128 pg/mL (higher than adults) 4

Males have significantly higher plasma metanephrine levels than females 3.

Typical Reference Ranges from Supine Sampling

Based on the landmark studies establishing these measurements 5:

  • Normetanephrine: 0.12-0.73 nmol/L (mean 0.38 nmol/L) in normal adults

    • Approximately 25-148 pg/mL (upper limit varies by age)
  • Metanephrine: 0.06-0.63 nmol/L (mean 0.19 nmol/L) in normal adults

    • Approximately 12-90 pg/mL (upper limit varies by gender)

Critical Clinical Considerations

Measurement Method Matters

Liquid chromatography with electrochemical detection (LC-ECD) or tandem mass spectrometry (LC-MS/MS) are strongly preferred over immunoassays 1. Immunoassays:

  • Substantially underestimate concentrations 1
  • Have lower diagnostic sensitivity 1
  • Have resulted in false-negative results in confirmed pheochromocytoma cases 1

Common Pitfalls to Avoid

  1. Improper sampling position: Drawing blood seated instead of supine is the most common cause of borderline false-positive results 1

  2. Using adult reference ranges in children: Pediatric upper limits differ significantly—metanephrine is higher (128 vs 90 pg/mL) and normetanephrine is lower (149 vs 180 pg/mL) in children 4

  3. Ignoring age for normetanephrine: Failure to use age-adjusted cutoffs leads to excessive false-positives in older adults 2

  4. Medication interference: Tricyclic antidepressants, acetaminophen, and other drugs can elevate results 1

  5. Physiological stress: Intensive care settings and extreme illness can markedly elevate metanephrines without pheochromocytoma 1

Harmonization Across Laboratories

Recent harmonization studies demonstrate that LC-MS/MS methods show excellent agreement between laboratories with mean bias <2% for both metanephrine and normetanephrine 6. However, interrater agreement in test interpretation for normetanephrine is only 84%, improving with harmonized age-specific cutoffs 6. This underscores the importance of using laboratory-specific, position-specific, and age-adjusted reference intervals rather than generic cutoffs.

Dietary Considerations

Fasting is only required if 3-methoxytyramine is being measured along with metanephrines 1. For standard metanephrine and normetanephrine measurements alone, no dietary restrictions are necessary.

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.