For intravenous use, dilute regular insulin (Humulin R U-100) in 5% dextrose in water at concentrations between 0.1 unit/mL to 1 unit/mL using polyvinyl chloride (PVC) infusion bags 1.
Preparation Guidelines
Concentration Range
- Minimum concentration: 0.1 unit/mL (100 units in 1000 mL D5W)
- Maximum concentration: 1 unit/mL (100 units in 100 mL D5W)
- The FDA label specifically authorizes this concentration range for IV infusion systems 1
Container Requirements
- Use polyvinyl chloride (PVC) infusion bags specifically 1
- Avoid glass bottles when possible, as insulin adheres significantly to glass surfaces
Stability After Preparation
- Refrigerated: Stable for 48 hours at 2-8°C (36-46°F)
- Room temperature: Can be used for an additional 48 hours after refrigeration 1
- Total usable time: 96 hours maximum from preparation
Important Considerations for Insulin Adherence
Factors That Reduce Insulin Loss to Container Surfaces
Research demonstrates that insulin adherence to containers can be substantial, but several factors minimize this loss 2:
- Higher insulin concentrations (25-300 units/liter) reduce adherence
- Larger fill volumes in D5W decrease the percentage of insulin lost
- Adding potassium chloride (when clinically appropriate) significantly decreases insulin adherence from D5W solutions 2
Practical Implications
When preparing insulin infusions at the lower end of the concentration range (0.1 unit/mL = 100 units/L), expect up to 25% insulin adherence to container surfaces. Using full bottles/bags and adding KCl when therapeutically indicated can reduce this loss 2.
Visual Inspection Before Use
- Never use if the solution has become viscous, thickened, or cloudy
- Use only if clear and colorless 1
- Inspect for particulate matter before administration
Clinical Dosing Context
While the question asks about dilution rather than dosing, note that current guidelines recommend fixed-rate IV insulin infusion at 0.05-0.1 units/kg/hour for DKA management, with reduction to 0.05 units/kg/hour when glucose falls below 14 mmol/L (252 mg/dL) 3. The dilution concentration you choose should facilitate accurate delivery of these rates based on your infusion pump capabilities.