In a patient who underwent left hip open reduction internal fixation (ORIF) with posterior capsule and short external rotators re‑approximated using #5 Ethibond sutures through bone, tensor fasciae latae and gluteus maximus closed with #2 StrataFix barbed absorbable suture, subcutaneous closure with 2‑0 Vicryl, skin closed with 4‑0 Monocryl subcuticular stitch, Exofin glue and Mepilex dressing applied, does any of this material need to be removed?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: November 23, 2026 • View editorial policy

Have a follow-up question?

Our Medical A.I. is used by practicing medical doctors at top research institutions around the world. Ask any follow up question and get world-class guideline-backed answers instantly.

No Routine Removal Required

None of the materials used in this left hip ORIF require routine removal. All sutures employed are either absorbable or designed for permanent tissue incorporation, and the skin closure materials are either absorbable or will naturally separate 1, 2, 3, 2.

Breakdown by Material Type

Deep Tissue Sutures (No Removal Needed)

  • #5 Ethibond (posterior capsule/external rotators): This non-absorbable braided polyester suture is intended for permanent tissue fixation when passed through bone. It provides long-term structural support and does not require removal 4, 5. The suture becomes incorporated into the healing tissue and maintains capsular integrity to prevent dislocation.

  • #2 StrataFix (tensor fascia/gluteus maximus): This is a barbed absorbable suture that provides knotless tissue approximation 6, 7. It gradually loses tensile strength over weeks to months and is completely absorbed by the body—no removal necessary. Recent evidence shows StrataFix reduces blood loss and provides effective fascial closure in hip arthroplasty 7.

Subcutaneous and Skin Closure (No Removal Needed)

  • 2-0 Vicryl (subcutaneous layer): This is polyglactin 910, a synthetic absorbable suture that maintains approximately 50-75% tensile strength at one week and is fully absorbed within 56-70 days 1, 2. Guidelines support absorbable subcutaneous sutures without removal 1.

  • 4-0 Monocryl (subcuticular skin closure): This is poliglecaprone 25, a monofilament absorbable suture ideal for subcuticular closure 1, 2. It provides wound support during critical healing phases and absorbs completely—no suture removal required. Evidence demonstrates subcuticular continuous sutures reduce wound dehiscence compared to interrupted techniques 2.

  • Exofin glue (topical skin adhesive): This cyanoacrylate-based tissue adhesive naturally sloughs off as the epidermis regenerates over 5-10 days 3, 2. It requires no removal and provides an additional barrier against bacterial contamination.

  • Mepilex dressing: This is a soft silicone foam dressing that should be changed per standard wound care protocols (typically removed at first dressing change in 24-48 hours or as clinically indicated).

Clinical Monitoring Points

Watch for these scenarios that might require intervention:

  • Suture abscess or "spitting suture": Occasionally, braided non-absorbable sutures like Ethibond can cause localized inflammation or work their way to the surface months to years later. If a suture granuloma develops or suture material extrudes through the skin, only that specific exposed portion should be trimmed—not the entire deep repair 2.

  • Wound complications: If superficial wound infection, dehiscence, or necrosis occurs, manage the complication itself rather than removing deep structural sutures 2, 3. The deep Ethibond repair is critical for hip stability and should remain intact unless there is deep infection requiring surgical debridement 8.

  • Deep infection: Only in the rare event of deep prosthetic joint infection would removal of all hardware and potentially some suture material be considered as part of a comprehensive irrigation and debridement 9.

Suture Removal Timeline Summary

Material Location Action Required
#5 Ethibond Deep (capsule/rotators) None - permanent fixation
#2 StrataFix Deep (fascia/muscle) None - absorbs over weeks
2-0 Vicryl Subcutaneous None - absorbs in 8-10 weeks
4-0 Monocryl Skin (subcuticular) None - absorbs in 3-4 months
Exofin glue Skin surface None - sloughs naturally
Mepilex External dressing Remove at dressing change

The surgical technique described follows evidence-based practices for hip arthroplasty closure, with appropriate material selection that eliminates the need for suture removal while maintaining structural integrity and reducing infection risk 3, 2, 6, 7.

References

Research

Capsular and fascial closure with barbed sutures reduces blood loss compared to traditional interrupted sutures in total hip arthroplasty.

Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association, 2025

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.