Fluorescein is the Orange Dye Used to Detect Corneal Abrasions
Fluorescein sodium (1-2% solution or saline-moistened strip) is the standard orange ophthalmic dye used to detect corneal abrasions and epithelial defects. 1
How Fluorescein Works
Fluorescein stains areas where the corneal epithelium is disrupted, allowing the dye to permeate through broken intercellular junctions into the underlying tissue. When viewed under a cobalt blue filter on a slit lamp or Wood's lamp, areas of epithelial loss appear bright green-yellow, making corneal abrasions readily visible 1.
Application Technique
- Use a saline-moistened fluorescein strip applied to the inferior tarsal conjunctiva, or instill 1-2% sodium fluorescein solution topically
- Examine the ocular surface through a biomicroscope using a cobalt blue filter
- Staining becomes more apparent after approximately 2 minutes and is more intense when observed with a yellow filter 1
- Apply fluorescein before instilling any other drops, especially anesthetics, as these can affect tear film assessment 1
Important Clinical Pearls
Mild fluorescein staining can occur in normal eyes, particularly in the morning, so clinical correlation is essential 1. The pattern and location of staining help differentiate between various pathologies:
- Corneal abrasions: Focal areas of bright uptake corresponding to epithelial defects
- Dry eye: Exposure-zone punctate or blotchy staining pattern
- Infectious keratitis: May show infiltrate with overlying epithelial defect 2
Why Not Rose Bengal?
While rose bengal is mentioned in the evidence as an alternative vital dye, it is not the standard choice for corneal abrasions. Rose bengal stains cells lacking mucous coating and is more intense on the conjunctiva than cornea 1. Additionally, it causes significant ocular irritation requiring topical anesthetic prior to instillation 1, making it impractical for routine corneal abrasion evaluation.