Impella 5.5 Arterial Access: Axillary Artery Only
The Impella 5.5 is inserted via the axillary artery (typically right-sided) using a surgical cutdown with a 10mm Dacron graft anastomosed to the vessel—it cannot be placed via the right internal jugular vein. 1, 2
Correct Insertion Pathway
The Impella 5.5 is a left-ventricular micro-axial flow pump that requires arterial access to reach the left ventricle across the aortic valve. The standard approach involves:
- Right axillary artery access (preferred to avoid crossing the aortic arch) 2, 3
- Surgical cutdown with 10mm Dacron graft anastomosed to the axillary artery 2
- The graft is extracted through adjacent skin via counterincision
- A 23Fr introducer is used to advance a curved guidewire through the aortic valve into the LV
- Device is positioned under fluoroscopy and echocardiography guidance 2
Alternative Arterial Access Sites
When standard right axillary access is not feasible:
- Left axillary artery can be used with comparable outcomes (delivery time and complication rates are similar) 3
- Trans-innominate (cervical) approach via the innominate artery for patients with small axillary vessels (<6-7mm diameter), particularly in pediatric populations 4
- Direct aortic insertion (surgical approach)
Minimum vessel diameter: While traditionally 7mm was recommended, recent data shows successful insertion in vessels as small as 6.3mm (mean) with no difference in outcomes 3
Why Not Internal Jugular Vein?
The right internal jugular vein provides venous access only and cannot be used for the Impella 5.5, which is a left-sided device requiring arterial access to the systemic circulation.
The confusion may arise because the ProtekDuo cannula (a completely different device) is inserted via the right internal jugular vein for right ventricular support. The ProtekDuo drains from the right atrium and reinfuses into the pulmonary artery, bypassing the failing RV 1. When biventricular support is needed, a ProtekDuo (via right IJ) can be paired with an Impella 5.5 (via axillary artery) to provide comprehensive BiVAD support 1.
Clinical Context for Impella 5.5 Use
According to 2026 European Heart Journal guidelines, the Impella 5.5 is used for:
- Left ventricular support in cardiogenic shock (SCAI stages C-E)
- Part of BiVAD configurations when combined with RV support devices
- Facilitates patient mobilization compared to smaller Impella devices 1
- Provides up to 5.5 L/min of cardiac augmentation 5
Key Technical Points
- Delivery time: Median 7 minutes (range 4-12 minutes) from first wire to device activation 3
- Support duration: Typically 8-13 days median 4, 3
- Anticoagulation required throughout support period to prevent pump thrombosis 5
- Complications to monitor: Stroke, limb ischemia, bleeding, infection, device malposition 1, 3
Common Pitfall
Do not confuse the Impella 5.5 (arterial, left-sided support) with the Impella RP (venous, right-sided support) or ProtekDuo (venous, right-sided support). Only the latter two can be placed via venous access routes. The Impella 5.5 absolutely requires arterial access via axillary artery or alternative arterial sites 1, 6, 2.