When the Respiratory Exchange Ratio Deviates from 0.8
The respiratory exchange ratio (RER) deviates from the assumed value of 0.8 primarily during non-steady state conditions, specifically when RER exceeds 1.0 due to lactic acidosis and/or hyperventilation, or falls below 0.8 depending on metabolic substrate utilization. 1
Understanding RER Under Steady State Conditions
Under true steady state conditions, RER equals the respiratory quotient (RQ) and reflects the metabolic fuels being utilized 1:
- RQ = 1.0: Predominantly carbohydrate metabolism
- RQ = 0.7: Fat metabolism
- RQ = 0.8: Protein metabolism or mixed substrate utilization
The assumed value of 0.8 represents a typical mixed diet metabolism at rest. However, this assumption only holds when blood and gas transport systems are keeping pace with tissue metabolism 1.
Primary Conditions Causing RER to Exceed 1.0
RER values greater than 1.0 occur due to two main mechanisms 1:
1. Lactic Acidosis During High-Intensity Exercise
When exercise intensity increases beyond the anaerobic threshold, lactic acid production rises. The bicarbonate buffering system generates excess CO₂ through the reaction:
H⁺ + HCO₃⁻ ↔ H₂CO₃ ↔ CO₂ + H₂O
This excess CO₂ production increases VCO₂ disproportionately to VO₂, driving RER above 1.0 1. A peak RER of 1.10 indicates excellent subject effort during cardiopulmonary exercise testing 2, though values can reach higher levels with maximal exertion.
2. Hyperventilation
Hyperventilation reduces body CO₂ stores (manifested as arterial hypocapnia), releasing stored CO₂ and artificially elevating VCO₂ relative to VO₂ 1. This occurs independently of metabolic acidosis.
Critical clinical caveat: The 20-fold higher tissue solubility of CO₂ compared to O₂ makes RER particularly sensitive to these non-metabolic CO₂ sources 1.
Conditions Causing RER to Fall Below 0.8
RER drops below 0.8 when:
- Increased fat oxidation occurs (RQ approaches 0.7) 1
- Measurement errors in closed system respirometry underestimate VCO₂ due to CO₂ storage in tissues during prolonged closure periods 3
- Non-steady state conditions where CO₂ stores are being replenished rather than released
Clinical Application Pitfalls
The 0.8 Assumption in Alveolar Gas Equations
When calculating P(a-a)O₂, assigning a fixed value of 0.8 to R is common practice but requires caution 1. If the actual R value is 1.0, the error in P(a-a)O₂ estimation would be approximately 10 mm Hg 1. This assumption should only be used as a rough estimate at rest, never during exercise.
Exercise Testing Interpretation
- RER < 1.0 at test termination may indicate submaximal effort, unless the test was stopped due to abnormal hemodynamic or ECG responses 4
- RER ≥ 1.0 validates peak VO₂ measurements and confirms adequate subject effort 4
- The absence of RER overshoot during recovery in heart failure patients indicates worse cardiorespiratory fitness and poorer prognosis 5
Practical Recommendations
Always measure RER directly during cardiopulmonary exercise testing rather than assuming 0.8 1. Report RER as a function of VO₂ throughout the test 1. When RER exceeds 1.0 during clinical testing, consider both lactic acidosis and hyperventilation as contributing factors, recognizing that both mechanisms often coexist at high exercise intensities 1.
For calculations requiring R values (such as alveolar gas equations), use measured values whenever possible. When measurements are unavailable, acknowledge the limitation and potential 10+ mm Hg error in derived variables 1.