CPT Codes for Visual Field Testing in Non-Ophthalmology Outpatient Settings
Yes, there are specific CPT codes for visual field testing that can be used in outpatient office settings by non-ophthalmology providers: CPT code E6691 for standard automated perimetry (SAP) and CPT code E6690 for kinetic perimetry.
Available CPT Codes
The two primary procedural codes for visual field testing are:
- E6691: Standard automated perimetry (SAP) - the most commonly used method
- E6690: Kinetic perimetry (e.g., Goldmann visual fields)
These codes are not restricted to ophthalmology practices and can be billed by any qualified provider performing visual field testing in an outpatient setting 1.
Clinical Context and Usage Trends
Standard automated perimetry (E6691) has become the dominant testing modality, with utilization increasing substantially over the past decade while kinetic perimetry use has declined 1. Between 2010 and 2019, SAP procedures increased from 93,459 to 216,433 annually, while kinetic perimetry decreased from 6,364 to 3,792 procedures 1.
When to Use Each Code:
E6691 (SAP) should be used for:
- Automated threshold testing with white-on-white stimuli
- Central visual field assessment (30-degree, 24-degree, or 10-degree programs)
- Most routine glaucoma and neurological visual field assessments 2
E6690 (Kinetic perimetry) should be used for:
- Patients who cannot reliably perform automated perimetry
- When automated equipment is unavailable
- Manual combined kinetic and static threshold testing 2
Important Coding Considerations
Documentation requirements are critical for reimbursement. The testing must be medically necessary, properly documented, and performed by qualified personnel. Common barriers to reimbursement include inconsistent documentation and lack of clarity about the specific testing methodology used 3.
Key Documentation Elements:
- Medical necessity for the test
- Specific testing strategy used (e.g., 24-2,30-2,10-2 program)
- Reliability indices
- Clinical interpretation of results
- How results impact patient management
Common Pitfalls to Avoid
- Repeat testing on the same day: When initial results are unreliable due to artifacts (lens rim, ptosis), address the underlying cause before repeat testing rather than billing multiple tests 2
- Inadequate documentation: Ensure clear documentation of why the test was performed and how it influenced clinical decision-making
- Using outdated or inappropriate testing methods: SAP is the standard of care; kinetic perimetry should only be used when SAP is not feasible 2
The codes are specialty-agnostic and can be billed by primary care, neurology, or any other specialty performing visual field testing, though proper training in test administration and interpretation is essential for accurate results and appropriate reimbursement.