Does Paraguard (Copper Intrauterine Device (IUD)) need to be placed at the fundus to be effective?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: August 15, 2025View editorial policy

Personalize

Help us tailor your experience

Which best describes you? Your choice helps us use language that's most understandable for you.

Fundal Placement of ParaGard IUD for Maximum Effectiveness

Yes, ParaGard should be placed at the fundus to maximize effectiveness and minimize the risk of expulsion. 1 High fundal placement of the IUD has been shown to decrease expulsion rates, which directly impacts contraceptive effectiveness.

Importance of Fundal Placement

Evidence Supporting Fundal Placement

  • The Society for Maternal-Fetal Medicine (SMFM) specifically recommends fundal placement of IUDs to decrease expulsion rates 1
  • During insertion procedures, providers are instructed to:
    • Pass the device through the cervix
    • Confirm fundal placement before releasing the device
    • Use transabdominal ultrasound when available to ensure proper fundal placement 1

Consequences of Non-Fundal Placement

  • Improper placement increases risk of:
    • Expulsion (partial or complete)
    • Reduced contraceptive efficacy
    • Increased bleeding and pain
    • Early discontinuation

Verification of Placement

Immediate Verification Methods

  • Manual verification: Palpating the uterine fundus abdominally while confirming device position 1
  • Ultrasound verification: Transabdominal ultrasound is recommended to guide insertion and ensure fundal placement 1

Post-Insertion Considerations

  • Studies have shown that ultrasound identification of incorrectly placed IUDs and subsequent removal significantly decreases expulsion rates 2
  • However, care must be taken not to remove IUDs unnecessarily, as this may result in women not returning for replacement 2

Clinical Implications

Insertion Technique

For proper fundal placement:

  1. Visualize the cervix
  2. Grasp the anterior lip with ring forceps
  3. Pass the device through the cervix under visualization
  4. Confirm fundal placement before releasing the device
  5. Move laterally when removing forceps to avoid displacement 1

Special Considerations

  • Uterine cavity width varies significantly among women (mean width 22.2mm, range 6.0-41.1mm) 3
  • Approximately 32% of nulliparous women have uterine cavity width <20mm 3
  • Discrepancy between IUD size and uterine cavity can lead to side effects and early discontinuation 3

Risks and Benefits

Benefits of Proper Placement

  • Decreased expulsion rates
  • Higher continuation rates
  • Maintained contraceptive efficacy (failure rates <1%) 1

Potential Complications

  • Side effects like bleeding and pain may decrease over time during menses but can persist during intermenstrual intervals 4
  • Expulsion risk is higher with immediate postpartum insertion but benefits often outweigh risks 1

Common Pitfalls to Avoid

  1. Failure to confirm fundal placement: Always verify placement either manually or with ultrasound
  2. Improper insertion technique: Follow established protocols for insertion
  3. Ignoring anatomical variations: Consider uterine size and shape, especially in nulliparous women
  4. Overlooking partial expulsion: Partial expulsion can reduce effectiveness while appearing to be in place

In conclusion, proper fundal placement of ParaGard is critical for maximizing effectiveness and minimizing complications. Verification of placement should be standard practice during insertion procedures.

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.