Is the Adrenocorticotropic Hormone (ACTH) lab test accurate in patients on hormone replacement therapy (HRT)?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: August 15, 2025View editorial policy

Personalize

Help us tailor your experience

Which best describes you? Your choice helps us use language that's most understandable for you.

ACTH Lab Test Accuracy in Patients on Hormone Replacement Therapy

ACTH lab testing can be inaccurate in patients on hormone replacement therapy, particularly those on glucocorticoids, and alternative testing methods or careful interpretation is necessary for accurate diagnosis. 1

Impact of Different Hormone Replacement Therapies on ACTH Testing

Glucocorticoid Replacement

  • Exogenous glucocorticoids directly suppress the hypothalamic-pituitary-adrenal (HPA) axis through negative feedback
  • This suppression leads to decreased ACTH production, resulting in falsely low ACTH levels
  • Even low-dose glucocorticoid replacement can affect ACTH levels, making interpretation challenging 2

Growth Hormone Replacement

  • GH replacement therapy can affect ACTH and adrenal function in different ways:
    • In ACTH-sufficient patients, GH replacement increases DHEAS levels (by 32% at 6 months)
    • In ACTH-deficient patients, GH replacement has minimal effect on adrenal androgen production 3
  • This suggests GH may stimulate adrenal androgen production when ACTH is present or affect cortisol metabolism through 11β-HSD type 1 inhibition

Sex Hormone Replacement

  • Estrogen-containing medications can affect dexamethasone suppression test results by altering cortisol binding globulin levels
  • This can complicate the interpretation of ACTH stimulation tests when evaluating adrenal function 2

Technical Issues Affecting ACTH Testing Accuracy

Assay-Specific Interferences

  • Different ACTH assays can produce significantly different results in the same patient
  • The Siemens ACTH Immulite assay has been documented to produce falsely elevated results compared to Roche Cobas or Tosoh AIA assays 4
  • These discrepancies have led to misdiagnosis, unnecessary testing, and even inappropriate surgical interventions

Potential Interfering Factors

  • Heterophile antibodies
  • Pro-opiomelanocortin (POMC) fragments
  • ACTH fragments
  • Cross-reactivity with other hormones in certain assays 4

Recommended Approach for ACTH Testing in Patients on HRT

Before Testing

  • Document all current hormone replacement therapies
  • Consider temporarily adjusting or holding certain medications if clinically appropriate:
    • For glucocorticoids: consult with endocrinologist about potential temporary adjustment
    • For estrogen-containing medications: consider testing interpretation issues 2

Testing Options

  • High-dose (250-μg) ACTH stimulation test is preferred over low-dose (1-μg) test for diagnosis of adrenal insufficiency 2
  • Consider using multiple testing modalities rather than relying solely on ACTH levels:
    • Morning serum cortisol
    • 24-hour urinary free cortisol
    • Late-night salivary cortisol 2

Interpretation Considerations

  • Compare results with appropriate reference ranges for patients on specific hormone therapies
  • Consider using alternative ACTH assays if results are inconsistent with clinical picture 4
  • In cases of suspected Cushing's syndrome, follow established diagnostic algorithms that incorporate multiple tests 2

Special Situations

ACTH Testing After Recent Glucocorticoid Use

  • ACTH responsiveness may be impaired for 8-12 days after stopping exogenous ACTH administration 5
  • This suggests caution in interpreting ACTH tests in patients who have recently discontinued glucocorticoid therapy

Autoregulation of ACTH

  • Evidence suggests ACTH can inhibit its own secretion through ultra-short loop feedback 6
  • This autoregulation may further complicate interpretation of ACTH levels in patients with altered HPA axis function

Clinical Implications and Recommendations

  • For suspected adrenal insufficiency: Use the high-dose (250-μg) ACTH stimulation test rather than low-dose testing 2
  • For suspected Cushing's syndrome: Follow established diagnostic algorithms using multiple tests including 24-hour UFC, late-night salivary cortisol, and dexamethasone suppression tests 2
  • When results are inconsistent: Consider using alternative ACTH assays or additional testing modalities 4
  • For monitoring: Regular follow-up should include assessment of well-being, weight, blood pressure, and serum electrolytes 1

By understanding these limitations and following appropriate testing protocols, clinicians can improve the accuracy of ACTH testing in patients on hormone replacement therapy and avoid diagnostic errors that could lead to inappropriate treatment decisions.

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.

Have a follow-up question?

Our Medical A.I. is used by practicing medical doctors at top research institutions around the world. Ask any follow up question and get world-class guideline-backed answers instantly.