Proper Administration of Oral Tox 10 Panel by Premier Biotech
To properly administer an oral toxicology 10 panel by Premier Biotech, follow the single-use device protocol by using the collection device for one patient only and disposing of it appropriately after sample collection.
Preparation and Setup
- Perform proper hand hygiene before handling the test kit
- Ensure adequate lighting and a clean, firm surface for supplies 1
- Verify the test kit is within its expiration date before use 1
- Prepare all necessary materials:
- Oral fluid collection device
- Gloves
- Timer
- Biohazard disposal container
Patient Preparation
- Instruct the patient to avoid eating, drinking, smoking, or using oral products (including mouthwash, tobacco, or gum) for at least 10 minutes prior to collection
- Have the patient rinse their mouth with water if they have recently consumed food or beverages
- Explain the procedure to the patient to ensure cooperation
Collection Procedure
- Don clean gloves before handling the collection device
- Remove the collection device from its sealed package immediately before use
- Hand the collection device to the patient or assist them with proper placement in the mouth
- Instruct the patient to place the absorbent pad between the lower cheek and gum
- Have the patient keep the device in place until the indicator shows sufficient sample collection (typically 2-5 minutes)
- Once collection is complete, take the device from the patient while maintaining aseptic technique
Handling the Sample
- Handle the collected sample as a biohazard specimen
- During transport, place the specimen in a sturdy, leakproof container labeled with appropriate identification 2
- If the specimen container is visibly contaminated, clean and disinfect the outside of the container or place it in an impervious bag labeled with the biohazard symbol 2
- Transport the sample according to chain of custody requirements if being used for legal or employment purposes
Documentation
- Document the date and time of collection
- Record the collector's name and signature
- Note any unusual circumstances during collection
- Complete all required chain of custody forms if applicable
Disposal of Materials
- Dispose of all single-use devices appropriately after use with one patient only 2
- Place all potentially contaminated materials in appropriate biohazard containers
- Never reuse collection devices between patients to prevent cross-contamination
Common Pitfalls and How to Avoid Them
- Insufficient sample collection: Ensure the indicator on the collection device shows adequate sample volume
- Contamination of sample: Maintain proper hand hygiene and use aseptic technique throughout the procedure
- Invalid results due to recent oral consumption: Enforce the waiting period before collection
- Chain of custody errors: Double-check all documentation and properly seal specimens according to protocol
Following these specific steps will ensure proper administration of the oral toxicology 10 panel by Premier Biotech while maintaining patient safety and sample integrity.