What are the characteristic findings of an arterial blood gas (ABG) in methemoglobinemia?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: September 19, 2025View editorial policy

Personalize

Help us tailor your experience

Which best describes you? Your choice helps us use language that's most understandable for you.

Characteristic ABG Findings in Methemoglobinemia

The arterial blood gas (ABG) in methemoglobinemia characteristically shows normal PaO2 and PaCO2 values with decreased oxygen saturation and an elevated alveolar-arterial oxygen gradient (P[A-a]O2), along with chocolate-brown colored blood that does not change color when exposed to air. 1

Key ABG Findings

  • Blood appearance: Chocolate-brown colored blood that remains dark despite exposure to oxygen 1, 2
  • PaO2: Often normal or even elevated (can be >300 mmHg with supplemental oxygen) 2
  • PaCO2: Usually normal (around 40 mmHg) 2
  • pH: Typically normal in early/mild cases; metabolic acidosis may develop in severe cases 1
  • Oxygen saturation:
    • Measured saturation (by co-oximetry): Significantly decreased
    • Calculated saturation (from ABG): Often normal 3
  • Saturation gap: Discrepancy between pulse oximetry readings (typically 85-90% regardless of oxygen therapy) and calculated oxygen saturation from ABG 3
  • Methemoglobin level: Elevated (normal is <1.5%; symptomatic at >10%) 1

Clinical Correlation with ABG Findings

The severity of clinical presentation correlates with methemoglobin levels 1, 4:

MetHb Level Clinical Manifestations
10-20% Cyanosis, chocolate-brown blood
20-30% Anxiety, headache, fatigue, dizziness
30-50% Tachycardia, dyspnea, confusion
50-70% Metabolic acidosis, arrhythmias, seizures, coma
>70% Severe hypoxic symptoms, death

Diagnostic Clues

  1. Saturation gap: The hallmark finding is the discrepancy between:

    • Normal PaO2 on ABG
    • Low oxygen saturation by pulse oximetry (typically plateaus around 85-90%)
    • Normal calculated oxygen saturation on ABG 3
  2. Oxygen-resistant cyanosis: Cyanosis that does not improve with oxygen supplementation 3

  3. Co-oximetry: The gold standard for diagnosis, which directly measures methemoglobin levels 5

Common Pitfalls in ABG Interpretation

  • Relying solely on pulse oximetry: Pulse oximetry is unreliable in methemoglobinemia as it typically reads around 85% regardless of the true methemoglobin level 3

  • Missing the saturation gap: Failure to recognize the discrepancy between normal PaO2 and decreased measured oxygen saturation 3

  • Overlooking blood color: Not noting the characteristic chocolate-brown appearance of blood samples, which is a critical diagnostic clue 2

  • Attributing symptoms to other causes: When ABG shows normal PaO2 but patient has symptoms of hypoxia, methemoglobinemia should be considered 1

Clinical Implications

The ABG findings reflect the underlying pathophysiology: methemoglobin contains iron in the ferric (Fe3+) rather than ferrous (Fe2+) state, which:

  1. Cannot bind oxygen
  2. Shifts the oxygen-dissociation curve to the left
  3. Results in decreased oxygen delivery to tissues despite normal PaO2 1

This creates a state of "functional anemia" without actual decrease in hemoglobin concentration, leading to tissue hypoxia despite adequate oxygen in the blood 1, 4.

References

Guideline

Guideline Directed Topic Overview

Dr.Oracle Medical Advisory Board & Editors, 2025

Research

Methemoglobinemia and transesophageal echo.

Proceedings of the Western Pharmacology Society, 2007

Guideline

Urine Color and Hydration Status

Praxis Medical Insights: Practical Summaries of Clinical Guidelines, 2025

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.

Have a follow-up question?

Our Medical A.I. is used by practicing medical doctors at top research institutions around the world. Ask any follow up question and get world-class guideline-backed answers instantly.