What is the significance of Positive End-Expiratory Pressure (PEEP) in the Cardiovascular Intensive Care Unit (CVICU)?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: October 16, 2025View editorial policy

Personalize

Help us tailor your experience

Which best describes you? Your choice helps us use language that's most understandable for you.

Significance of PEEP in CVICU

Positive End-Expiratory Pressure (PEEP) is critically important in the CVICU as it improves oxygenation, prevents alveolar collapse, reduces work of breathing, and can counterbalance intrinsic PEEP, though it must be carefully titrated to avoid adverse hemodynamic effects in cardiac patients.

Physiological Effects of PEEP in CVICU

  • PEEP maintains positive alveolar pressure at end-expiration, preventing alveolar collapse and improving functional residual capacity, which is particularly important in ventilator-dependent cardiac patients 1
  • In ventilator-dependent patients, PEEP counterbalances intrinsic PEEP (auto-PEEP), reducing the inspiratory threshold load during both spontaneous breathing and patient-triggered ventilation modes 1
  • PEEP significantly improves arterial and tissue oxygenation under hypoxic conditions, with studies showing increases in arterial oxygen saturation by approximately 5-7% with PEEP of 10 cmH2O 2

Hemodynamic Considerations in Cardiac Patients

  • High levels of PEEP can decrease cardiac output by increasing intrathoracic pressure, reducing venous return, and potentially worsening right ventricular function in patients with pulmonary hypertension or right heart failure 1
  • When mechanical ventilation is required in patients with cardiovascular compromise (such as pulmonary embolism), PEEP should be applied with caution as positive intrathoracic pressure may reduce venous return and worsen right ventricular failure 1
  • Despite concerns, research has shown that carefully titrated PEEP (even up to 32 torr/44 cmH2O in selected cases) can be used without adversely affecting cardiac output when combined with appropriate monitoring 3

PEEP Measurement and Titration in CVICU

  • Intrinsic PEEP can be measured using either end-expiratory airway occlusion technique or simultaneous recording of flow and pleural pressure 1
  • The American Thoracic Society recommends using plateau pressure measurements to guide ventilator settings and titrate PEEP levels 4
  • For patients without ARDS, plateau pressures should be maintained below 25 cmH2O, while for ARDS patients, plateau pressures should remain below 30 cmH2O to prevent ventilator-induced lung injury 4

Clinical Applications in CVICU

  • Application of low levels of PEEP (5-10 cmH2O) can significantly improve patient-ventilator interaction and reduce the magnitude of inspiratory effort during assisted ventilation and weaning 1
  • In patients with acute respiratory insufficiency, higher levels of PEEP (18 torr or greater) have been shown to significantly decrease ventilation-perfusion mismatch (QA/QT) 3
  • For patients with acute lung injury or ARDS in the CVICU, PEEP improves oxygenation and may reduce ventilator-induced lung injury, though studies show no significant mortality benefit between higher versus lower PEEP strategies 5, 6

Practical Implementation in CVICU

  • PEEP selection should be individualized based on the patient's specific condition, with consideration of recruitability assessment, especially in more severe cases 7
  • When implementing PEEP in cardiac patients, careful cardiovascular monitoring is essential to detect and address any adverse hemodynamic effects 1, 3
  • In patients with right ventricular dysfunction or pulmonary hypertension, lower PEEP levels may be preferable to minimize adverse effects on pulmonary blood flow 1

Common Pitfalls and Considerations

  • Excessive PEEP can lead to complications including pneumothorax (reported in 14% of patients receiving high PEEP therapy) and hemodynamic compromise 3
  • Patient-ventilator asynchrony can lead to inaccurate PEEP measurements; ensuring the patient is not actively breathing during measurement is crucial 4
  • When using PEEP in patients with cardiac conditions, the balance between respiratory benefits and potential cardiac effects must be carefully evaluated, with continuous monitoring of both systems 1

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.