What is the radiation dose of a lumbar X-ray (X-ray of the lower back)?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: March 25, 2025View editorial policy

Personalize

Help us tailor your experience

Which best describes you? Your choice helps us use language that's most understandable for you.

From the Guidelines

The typical radiation dose for a lumbar spine X-ray is approximately 1.5 millisieverts (mSv), though this can range from 0.7 to 2.0 mSv depending on the specific views taken and equipment used. This dose is relatively low compared to other medical imaging procedures, representing about half the radiation exposure of a standard CT scan of the lumbar spine. For context, humans receive about 3 mSv annually from natural background radiation 1. The radiation exposure from a lumbar X-ray is generally considered safe and justified when there is a clear medical need, such as evaluating back pain, suspected fractures, degenerative changes, or spinal alignment issues.

The benefit of accurate diagnosis typically outweighs the minimal risk from radiation exposure. However, healthcare providers aim to follow the ALARA principle (As Low As Reasonably Achievable) to minimize unnecessary radiation exposure, particularly for pregnant women and children who are more sensitive to radiation effects. Multiple or frequent X-rays should be avoided unless medically necessary, and alternative imaging methods like MRI or ultrasound might be considered in certain situations where they can provide adequate diagnostic information without radiation exposure. It's also important to note that the actual radiation dose can vary significantly depending on individual patient factors and the specifics of the imaging procedure, as highlighted by the American College of Radiology's discussion on the complexity of determining ionizing radiation dose in living humans 1.

Key considerations for minimizing radiation exposure include:

  • Using the lowest necessary dose for diagnostic purposes
  • Avoiding unnecessary repeat imaging
  • Considering alternative imaging modalities when appropriate
  • Following guidelines for imaging in specific clinical scenarios, such as the evaluation of low back pain, where routine imaging is not recommended for patients with nonspecific symptoms 1.

From the Research

Radiation Dose of Lumbar X-ray

  • The radiation dose of a lumbar X-ray can vary depending on the specific examination and the patient's characteristics 2, 3, 4.
  • According to a study published in 2013, the mean entrance surface air kerma (ESAK) of lumbar spine radiography was 76.3 μGy for anteroposterior (AP) views and 122.2 μGy for lateral (LAT) views 3.
  • The effective dose for lumbar spine radiography was reported to be around 1.1 mSv in a study published in 2014 5.
  • Another study published in 2008 estimated the effective radiation doses for AP and lateral lumbar radiographs to be 2.20 and 1.50 mSv, respectively 4.
  • A study published in 2014 found that the dose area product (DAP) for lumbar spine X-ray could be reduced by 50% to 123 ± 61 cGy · cm² for AP views and by 30% for lateral views to 229 ± 116 cGy · cm² by optimizing the X-ray technique 2.

Comparison with Other Imaging Modalities

  • Low-dose computed tomography (CT) of the lumbar spine has been shown to have superior image quality to lumbar spine radiography, with an effective dose of around 1 mSv 6, 5.
  • The effective dose for low-dose CT of the lumbar spine is comparable to that of lumbar spine radiography, making it a potential alternative for diagnostic imaging 6, 5.

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.