What are the optimal low and high frequency filter settings for a polysomnogram (PSG)?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: April 2, 2025View editorial policy

Personalize

Help us tailor your experience

Which best describes you? Your choice helps us use language that's most understandable for you.

From the Research

Polysomnogram filter settings should typically use a low frequency filter of 0.3 Hz and a high frequency filter of 35 Hz for most channels, as evidenced by recent studies 1. These settings are designed to capture the relevant physiological signals while minimizing artifacts. For EEG channels specifically, the low frequency filter is usually set at 0.3 Hz to allow detection of slow wave activity during sleep, while the high frequency filter is set at 35 Hz to include beta activity while reducing muscle artifact contamination. For EMG channels, a wider bandwidth is often used with a low frequency filter of 10 Hz and a high frequency filter of 100 Hz to better capture muscle activity. ECG channels typically use settings of 0.3 Hz for the low frequency filter and 70 Hz for the high frequency filter. These filter settings are crucial for proper signal acquisition as they help eliminate unwanted electrical noise while preserving the physiological signals of interest. Setting filters too narrowly can result in loss of important data, while setting them too widely can introduce excessive noise, as noted in a study on low frequency filtering of nasal pressure channels 2. Technicians may need to adjust these settings based on specific recording conditions or patient characteristics to optimize signal quality, and recent advancements in sleep staging algorithms may also impact the interpretation of polysomnogram data 1. Some key considerations for filter settings include:

  • Low frequency filter settings can affect the appearance of respiratory flow limitation 2
  • High frequency filter settings can impact the detection of beta activity and muscle artifact contamination
  • The choice of filter settings may depend on the specific sleep disorder being diagnosed, such as obstructive sleep apnea or insomnia 1
  • Recent studies have highlighted the importance of precision medicine in sleep disorders, which may involve the use of novel polysomnogram metrics and analyses 3.

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.