What are the guidelines for managing bubbles that appear during scleral (scleral intraocular lens) lens fitting?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: November 25, 2025View editorial policy

Personalize

Help us tailor your experience

Which best describes you? Your choice helps us use language that's most understandable for you.

Guidelines for Bubble Management During Scleral Lens Fitting

Bubbles trapped beneath scleral lenses during fitting should be minimized by ensuring adequate initial clearance (typically 200-400 μm centrally), proper lens insertion technique with complete fluid filling, and reassessment after 4 hours of wear when vault naturally decreases. 1, 2

Understanding Bubble Formation Mechanisms

Bubbles form beneath scleral lenses through several mechanisms that must be recognized during fitting:

  • Inadequate initial fluid filling during lens insertion is the most common cause, where air becomes trapped between the lens and corneal surface 3
  • Excessive central clearance (>400 μm) paradoxically increases bubble formation risk by creating unstable fluid dynamics and reducing oxygen transmission to the cornea 4
  • Insufficient clearance (<200 μm) can also trap bubbles as the lens settles and vault decreases over time 2, 4

Initial Fitting Assessment Protocol

The American Academy of Ophthalmology recommends specific baseline measurements before addressing bubble issues:

  • Obtain corneal topography/tomography to identify irregular surfaces that may trap air pockets during lens application 1
  • Measure horizontal visible iris diameter (HVID) and limbus width to select appropriate lens diameter, as improper sizing contributes to bubble entrapment 5
  • Perform slit-lamp biomicroscopy immediately after lens insertion to identify bubble location, size, and number 1

Optimal Clearance Parameters to Prevent Bubbles

Target central vault of 200-400 μm at initial fitting, recognizing that vault will decrease significantly during wear:

  • Mean vault reduction of 125 μm in ectasia patients and 68 μm in ocular surface disease patients occurs within 4 hours of wear 2
  • Initial vault of 680 μm decreases to 589 μm after 4 hours across all patients (p<0.001) 2
  • Excessive clearance (>400 μm) induces more endothelial blebs (median 1.00 bleb) compared to 200 μm clearance (median 0.00 blebs, p=0.02), indicating compromised oxygen dynamics 4

Lens Insertion Technique to Eliminate Bubbles

Proper insertion technique is critical for bubble prevention:

  • Fill the lens bowl completely with preservative-free saline before application, ensuring no air pockets remain in the fluid 6, 3
  • Apply the lens perpendicular to the ocular surface rather than at an angle to prevent air entrapment at the lens edge 3
  • Use a plunger or tripod finger technique for stable, controlled insertion that maintains fluid seal 3
  • If bubbles appear after insertion, remove and reinsert the lens rather than attempting to manipulate bubbles out 3

Timing of Final Bubble Assessment

Perform definitive bubble evaluation after 4 hours of lens wear, not at initial insertion:

  • The American Academy of Ophthalmology notes that final scleral lens assessment should occur after 4 hours when vault has stabilized 2
  • Vault measurements at 1 hour are unreliable predictors of final lens position and bubble behavior 2
  • 90% of eyes show vault reduction during the first 4 hours, which can either trap new bubbles or release existing ones 2

Diameter Selection Impact on Bubble Formation

Lens diameter significantly affects bubble dynamics:

  • Start with the smallest possible diameter based on HVID and limbus width, as larger lenses have more complex fluid dynamics that promote bubble formation 5
  • Mini-scleral lenses (16-18 mm) generally have better oxygen transmission and less bubble formation compared to larger designs 5
  • Consider larger diameters (18-18.5 mm) only when smaller lenses demonstrate persistent bubble issues or inadequate scleral landing 5

Clinical Significance of Bubble Presence

Small bubbles have varying clinical impact:

  • Central bubbles directly over the visual axis require lens refitting as they degrade optical quality 3
  • Peripheral bubbles may be tolerated if they remain stable and do not migrate centrally during wear 3
  • Bubbles associated with endothelial bleb formation (transient loss of endothelial cell specular reflection) indicate hypoxic stress and mandate reduced clearance 4
  • Bleb area (293 ± 28 μm²) is significantly smaller than normal cell area (370 ± 32 μm², p<0.0001), suggesting cellular stress from compromised oxygen delivery 4

Troubleshooting Persistent Bubbles

When bubbles persist despite proper technique:

  • Reduce central clearance by selecting a steeper base curve if bubbles appear with excessive vault 4
  • Increase clearance slightly if bubbles form from lens settling and corneal touch 2
  • Evaluate scleral toricity as asymmetric landing can create channels for air entry 5
  • Consider custom-designed lenses for patients with scleral irregularities (pterygia, glaucoma blebs) that create air pockets 7, 1

Common Pitfalls to Avoid

Critical errors in bubble management include:

  • Accepting initial bubble assessment without waiting for 4-hour vault stabilization leads to inappropriate lens modifications 2
  • Over-vaulting to avoid corneal touch paradoxically increases bubble formation and endothelial stress 4
  • Ignoring small peripheral bubbles that may migrate centrally as vault decreases during wear 2, 3
  • Failing to educate patients on proper insertion technique, as self-insertion errors are the primary cause of bubble formation 6, 3

Pediatric Considerations

In pediatric scleral lens fitting (≤16 years):

  • Average daily wear of 9 hours is achievable with proper training on bubble-free insertion 6
  • Children can become self-sufficient in lens insertion and removal with appropriate instruction, minimizing bubble-related complications 6
  • Vision may drop by 2+ lines after 4 hours in 45% of eyes due to tear debris collection, which can be confused with bubble-related optical degradation 6

References

Guideline

Scleral Lens Fitting Guidelines

Praxis Medical Insights: Practical Summaries of Clinical Guidelines, 2025

Research

Change in vault during scleral lens trials assessed with anterior segment optical coherence tomography.

Contact lens & anterior eye : the journal of the British Contact Lens Association, 2017

Research

CLEAR - Scleral lenses.

Contact lens & anterior eye : the journal of the British Contact Lens Association, 2021

Research

Corneal Endothelial Blebs Induced in Scleral Lens Wearers.

Optometry and vision science : official publication of the American Academy of Optometry, 2019

Research

Modern scleral lenses: Mini versus large.

Contact lens & anterior eye : the journal of the British Contact Lens Association, 2017

Research

Fluid filled scleral contact lens in pediatric patients: challenges and outcome.

Contact lens & anterior eye : the journal of the British Contact Lens Association, 2012

Guideline

Guideline Directed Topic Overview

Dr.Oracle Medical Advisory Board & Editors, 2025

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.

Have a follow-up question?

Our Medical A.I. is used by practicing medical doctors at top research institutions around the world. Ask any follow up question and get world-class guideline-backed answers instantly.