What is the sensitivity of Fluorodeoxyglucose (FDG) Positron Emission Tomography (PET) in cholangiocarcinoma?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: December 8, 2025View editorial policy

Personalize

Help us tailor your experience

Which best describes you? Your choice helps us use language that's most understandable for you.

Sensitivity of FDG PET in Cholangiocarcinoma

FDG-PET demonstrates limited overall sensitivity of 52% for detecting cholangiocarcinoma, with performance heavily dependent on tumor morphology—sensitivity reaches 85-95% for mass-forming/nodular lesions ≥1 cm but drops dramatically to only 18% for infiltrating-type tumors. 1

Sensitivity by Tumor Type and Location

Mass-Forming/Nodular Cholangiocarcinoma

  • Sensitivity is 85-95% for nodular intrahepatic cholangiocarcinoma (iCCA) when the mass is ≥1 cm 1
  • One high-quality study reported 92.3% sensitivity (24/26 cases detected) for histologically proven cholangiocarcinoma 2
  • Another study confirmed 85% sensitivity specifically for nodular morphology in cholangiocarcinoma 3

Infiltrating/Periductal Cholangiocarcinoma

  • Sensitivity plummets to only 18% for infiltrating-type cholangiocarcinoma, making FDG-PET unreliable for this morphology 3
  • The 2023 ESMO guidelines note that sensitivity is lower in infiltrating CCA compared to nodular forms 1
  • FDG-PET was falsely negative in intrahepatic infiltrating-type cholangiocarcinoma in multiple studies 4

Extrahepatic Cholangiocarcinoma

  • Sensitivity for detecting primary extrahepatic cholangiocarcinoma is lower than contrast-enhanced MDCT or MRI (p < 0.001) 5
  • The 2023 ESMO guidelines report sensitivity of approximately 80-90% for gallbladder carcinoma or nodular CCA ≥1 cm 1

Performance for Staging

Lymph Node Metastases

  • Meta-analyses show FDG-PET has limited sensitivity of only 52% for detecting lymph node metastases with specificity of 91% 1
  • Sensitivity for regional lymph node metastases in extrahepatic cholangiocarcinoma is significantly lower than MDCT or MRI 5
  • FDG-PET detected regional/hepatoduodenal lymph node metastases in only 2 of 15 cases (13% sensitivity) 2
  • However, specificity and positive predictive value for regional lymph nodes are significantly better with FDG-PET compared to MDCT and MRI (all p < 0.001) 5

Distant Metastases

  • FDG-PET outperforms CT for detecting distant metastases (88% vs. 79% sensitivity, respectively) 1
  • Sensitivity for distant metastases was 70% (7/10 cases) in one study, including peritoneal carcinomatosis and pulmonary metastases 2
  • Sensitivity for extrahepatic metastases in gallbladder carcinoma was 50% in eight patients 3

Critical Limitation: Carcinomatosis

  • FDG-PET was false negative for carcinomatosis in 3 of 3 patients (0% sensitivity) 3
  • Six of eight patients with extrahepatic metastases from gallbladder carcinoma had carcinomatosis, limiting PET utility 3

Important Clinical Caveats

False Positive Results

  • False positives occur in primary sclerosing cholangitis (PSC), particularly with acute cholangitis 3
  • Poor positive predictive value in patients with PSC, biliary prosthesis, or granulomatous disease 1
  • 58% (7/12) of patients showed FDG uptake along biliary stent tracts, creating interpretation challenges 3

Specificity

  • Overall specificity is high at 91-93% when excluding confounding conditions 1, 2
  • Specificity was 100% in one study when properly accounting for benign biliary lesions 2

Clinical Recommendations from Guidelines

  • The 2024 French Association for the Study of the Liver (AFEF) guidelines state that FDG-PET is NOT recommended for primary diagnosis of cholangiocarcinoma 1
  • FDG-PET may be useful for identifying nodal metastases, distant metastases, and disease recurrence, but utility for lymph node assessment remains to be fully evaluated 1
  • The 2023 ESMO guidelines similarly do not recommend FDG-PET for primary diagnosis 1
  • The 2014 Journal of Hepatology guidelines note limited clinical utility of CT/PET for diagnosis of iCCA when CT or MRI has already been performed 1

Practical Algorithm

For suspected cholangiocarcinoma:

  1. Use multiphase CT or MRI as first-line imaging (sensitivity 78% for CT, higher specificity with MRI) 1
  2. Reserve FDG-PET for detecting distant metastases when curative treatment is being considered 1
  3. Do NOT rely on FDG-PET for infiltrating-type tumors, patients with PSC, or those with biliary stents 3
  4. Interpret with extreme caution in the presence of acute cholangitis or granulomatous disease 3
  5. FDG-PET should not replace tissue diagnosis via biopsy 1

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.