Diagnostic Obstetric Imaging: Guidelines for Safe Use During Pregnancy
Primary Recommendation for Ultrasound
Ultrasound is the primary and safest imaging modality for obstetric evaluation throughout pregnancy, with no documented harmful effects when performed according to established safety protocols, though exposure should be kept as low as reasonably achievable (ALARA principle). 1, 2
Ultrasound Safety Profile
Established Safety
- Long-term follow-up studies of children exposed to ultrasound in utero demonstrate no detrimental effects on cognitive or physical development 1
- Diagnostic ultrasound is regarded as safe but is a form of energy with bioeffects on tissues, primarily mechanical and thermal effects 1, 3
- The key principle is that obstetric ultrasound should only be performed for medical reasons, not for non-medical purposes like entertainment or keepsake videos 2
Specific Safety Concerns During Embryogenesis
Higher energy exposure poses particular concern in these scenarios:
- First trimester scanning with long trans-vesical path (>5 cm) - increased tissue heating risk 2
- Doppler studies (pulsed, color, and power Doppler) - highest output energy, especially concerning in early pregnancy 1, 2
- Scanning tissue with minimal perfusion (embryonic tissue) - reduced heat dissipation capacity 2
- Maternal fever - baseline elevated tissue temperature increases thermal risk 2
Risk Mitigation Strategies
Operators can minimize potential bioeffects by:
- Limiting dwell time on any single anatomic structure, particularly in the first trimester 2
- Avoiding prolonged Doppler interrogation of embryonic structures before 10-11 weeks 2
- Monitoring equipment-generated thermal index (TI) and mechanical index (MI) displays 2
- Keeping TI <1.0 when possible, especially when scanning embryonic tissue 2
MRI Safety During Pregnancy
General Safety Profile
MRI without gadolinium contrast is safe throughout pregnancy and should be used when ultrasound is inadequate or additional information is needed. 1
Timing Considerations
- MRI is ideally performed at or after 22 weeks gestation for fetal evaluation 1
- First trimester MRI does not appear to be associated with increased risk of harm to the fetus 1
- MRI between 18-22 weeks may have value in certain clinical indications 1
Gadolinium Contrast - Critical Warning
Gadolinium-based contrast agents should be avoided during pregnancy due to documented fetal risks:
- Associated with small but significant absolute increase in adverse fetal and neonatal outcomes 1
- Linked to increased risk of rheumatological, inflammatory, or infiltrative skin conditions in offspring (adjusted hazard ratio 1.36) 1
- Associated with increased risk of stillbirth or neonatal death (adjusted relative risk 3.70) 1
- There are no documented fetal indications for gadolinium use; any use must be decided case-by-case for maternal indications only 1
Thermal Considerations
- MRI can theoretically increase temperature of maternal and fetal tissues 1
- No specific thermal limits are established for obstetric MRI, but the procedure should follow ALARA principles 1
Ionizing Radiation Exposure
Safety Thresholds
Standard diagnostic imaging with ionizing radiation is safe when fetal exposure remains below established thresholds:
- Exposure ≤50 mGy is considered safe at any trimester 1
- Typical fetal radiation doses from standard radiologic tests are far below the maximal cumulative threshold 1
Specific Radiation Risks by Dose
- <50 mGy: Minimal risk; estimated cancer incidence increase of 1.1-3 per 1000 (baseline childhood cancer risk is 1-2.5 per 1000) 1
- >50 mGy: Doubled relative risk of childhood cancer 1
- >100 mGy: Increased risk of mental retardation (estimated loss of 0.025 IQ points per mGy above 100 mGy) 1
- >150 mGy: Increased risk of malformations 1
- >200-500 mGy: May warrant consideration of pregnancy termination 1
CT Scanning in Pregnancy
CT should not be avoided when clinically indicated, as the risk-benefit balance favors maternal diagnosis and treatment:
- Thoracic, abdominal, and pelvic CT (with or without contrast) should be performed when indicated 1
- Radiation from diagnostic CT remains pronouncedly below thresholds associated with fetal damage 1
- Multidetector CT for suspected appendicitis confers doses of only 1.52-1.68 cGy at early gestation and 2-4 cGy at 3 months 1
Practical Algorithm for Imaging Selection
First-Line Imaging
- Ultrasound - for all routine obstetric evaluations and most suspected pathology 1
- Minimize Doppler use in first trimester; avoid before 10-11 weeks if possible 2
Second-Line Imaging (When Ultrasound Inadequate)
- MRI without gadolinium - for fetal anomalies, brain evaluation, large masses, or maternal obesity limiting ultrasound 1
- Preferred timing: ≥22 weeks, though earlier use acceptable when benefits outweigh risks 1
When Ionizing Radiation Required
- CT or X-ray - when rapid diagnosis critical for maternal health (trauma, suspected pulmonary embolism, acute abdomen) 1
- Document estimated fetal dose and inform pediatrician at birth 1
- Never delay necessary imaging due to pregnancy status 1
Common Pitfalls to Avoid
- Never perform ultrasound for non-medical purposes (entertainment, gender determination without medical indication) - violates ALARA principle 2
- Never use prolonged Doppler on embryonic structures in first trimester - highest thermal risk period 2
- Never use gadolinium contrast routinely - documented adverse outcomes 1
- Never delay medically necessary CT/X-ray - maternal health takes priority, and standard doses are below harm thresholds 1
- Never assume all ultrasound is completely risk-free - it is energy with bioeffects that must be respected through proper technique 3, 2
Educational Points for Limited-Resource Settings
In outskirt communities with limited diagnostic modalities:
- Standard ultrasound remains the cornerstone of prenatal imaging and is safe when performed properly 1, 2
- Operators must understand thermal and mechanical indices displayed on equipment 2
- MRI access should be pursued for cases where ultrasound is inadequate, particularly for suspected fetal brain anomalies 1, 4
- The radiation exposure from a single diagnostic X-ray or CT is not an indication for pregnancy termination - the doses are far below harmful thresholds 1