What could be causing elevated radiation exposure during a surgery using a fluoroscopy (fluoroscopic) machine?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: December 18, 2025View editorial policy

Personalize

Help us tailor your experience

Which best describes you? Your choice helps us use language that's most understandable for you.

Elevated Radiation Exposure During Fluoroscopy-Guided Surgery

The most likely cause of elevated radiation exposure is that the X-ray machine was positioned too close to the patient (not too far), combined with poor operator technique including excessive fluoroscopy time, improper collimation, and inadequate use of protective shielding.

Primary Causes of Excessive Radiation Exposure

Equipment Positioning (Inverse Square Law)

  • The X-ray source positioned too close to the patient dramatically increases radiation scatter to all personnel in the room 1
  • The inverse square law dictates that radiation exposure decreases exponentially with distance from the source 1
  • Proper positioning requires maximizing the distance between the X-ray tube and patient while minimizing the distance between patient and image detector 1
  • When the X-ray source is placed too far from personnel (not closer), exposure actually decreases—making option B incorrect 1

Operator Technique Factors

  • Excessive fluoroscopy time is the single greatest contributor to cumulative radiation exposure, accounting for 6.3 times more total radiation than cine imaging despite lower per-second dose rates 1
  • Poor collimation (leaving collimator leaves wide open) unnecessarily increases the radiation field size and scatter to all personnel 1
  • Certain radiographic projections, particularly left anterior oblique views, generate 2.6 to 6.1 times higher operator doses compared to right anterior oblique views 1
  • Failure to use last image hold capability results in continuous beam-on time when static images would suffice 1

Inadequate Protective Measures

  • Inconsistent use of lead aprons, thyroid shields, and leaded acrylic shields significantly increases exposure 1
  • Lead aprons provide approximately 95% reduction in radiation exposure when properly worn 1
  • Studies demonstrate that cardiologists are often inconsistent in their use of badges and appropriate shielding, leading to excessive exposures 1
  • Suspended leaded acrylic shields, when used, dramatically reduce scatter radiation to operators 1

Why Option A is Incorrect

Duration of wearing protective gear is not the mechanism of excessive exposure—rather, it's the failure to wear it consistently during the entire procedure 1. The guidelines emphasize that:

  • Protective equipment must be worn throughout the entire fluoroscopy procedure 1
  • The issue is not "wearing it long enough" but rather inconsistent compliance with using appropriate shielding 1
  • When properly applied protective measures are used consistently, excessive exposure should not occur regardless of caseload complexity 1

Critical Response to Overexposure

When radiation exposure exceeds normal thresholds, a systematic investigation of equipment performance and operator practices must be conducted immediately 1:

  • Review fluoroscopy time and cine time per case to identify patterns contributing to increased exposure 1
  • Evaluate equipment calibration and performance 1
  • Assess operator technique including beam positioning, collimation, and projection angles 1
  • Document use of protective shielding by all personnel 1
  • Consider temporary case reduction only after identifying and correcting the root cause 1

Common Pitfalls

  • Misconception that distance from the source doesn't matter: Personnel standing even a few feet from the primary beam receive 2% to 11% of primary operator exposure depending on beam angulation 1
  • Underestimating the impact of beam positioning: Small changes in X-ray tube-to-patient distance create exponential changes in scatter radiation 1
  • Assuming protective gear alone is sufficient: Even with proper shielding, poor technique (excessive fluoroscopy time, wide collimation) can result in excessive exposure 1
  • Failing to use pulsed fluoroscopy and dose-reduction features: Modern equipment offers substantial dose reduction capabilities that must be actively employed 1

References

Guideline

Guideline Directed Topic Overview

Dr.Oracle Medical Advisory Board & Editors, 2025

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.