What volume of 0.75% bupivacaine (local anesthetic) should be used for a spinal anesthetic in a patient who is 5 feet 9 inches tall?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: December 22, 2025View editorial policy

Personalize

Help us tailor your experience

Which best describes you? Your choice helps us use language that's most understandable for you.

Spinal Anesthesia Dosing with 0.75% Bupivacaine

Do not use 0.75% bupivacaine for spinal anesthesia in this patient—the appropriate concentration for spinal anesthesia is 0.5% bupivacaine, and the volume should be 3 mL (15 mg) for a patient of average height like 5'9". 1, 2

Critical Concentration Issue

The question asks about 0.75% bupivacaine, but this concentration is problematic for spinal anesthesia:

  • 0.75% bupivacaine (22.5 mg in 3 mL) produces excessively deep motor blockade and more pronounced hemodynamic effects compared to 0.5% solutions 2
  • Research demonstrates that 0.75% bupivacaine in glucose-free solution produces "very long-lasting blockade with deep motor engagement" but also "more marked effect on blood pressure" than other tested solutions 2
  • The standard concentration for spinal anesthesia is 0.5% bupivacaine, which provides adequate sensory and motor blockade with better hemodynamic stability 3, 2

Recommended Dosing for Standard Spinal Anesthesia

For a patient who is 5'9" (average height, approximately 70 kg):

  • Use 3 mL of 0.5% hyperbaric bupivacaine (15 mg total dose) 3, 2
  • This dose produces sensory blockade reaching T6-T8 on average within 15 minutes, adequate for most surgical procedures 2
  • Hyperbaric solutions (with 8.25% glucose) produce more predictable spread with fewer high blocks compared to isobaric solutions 1, 3

Alternative Incremental Dosing Approach

If using a spinal catheter technique (continuous spinal anesthesia):

  • Start with 1.25-2.5 mg bupivacaine every 3 minutes until adequate surgical level is achieved 1
  • Total doses typically range 7.5-15 mg for adequate anesthesia 1
  • This incremental approach minimizes risk of excessively high block and hemodynamic instability 1
  • The minimum effective dose via spinal catheter is approximately 11.7 mg for levobupivacaine, suggesting similar requirements for bupivacaine 4

Height Considerations

Patient height of 5'9" does not require dose adjustment:

  • This is average height for an adult, so standard dosing applies 2
  • Height primarily affects spread of block rather than total dose required 3, 2
  • Dose reductions are indicated for elderly patients, those with significant cardiac or hepatic disease, or debilitated patients—not based on height alone 1, 5

Safety Considerations

  • Maximum safe dose for any local anesthetic technique with bupivacaine is 2.5 mg/kg 6, 5
  • For a 70 kg patient, this equals 175 mg maximum—well above the 15 mg used for spinal anesthesia 6
  • Always calculate weight-based dosing to avoid exceeding maximum safe doses 5
  • The 15 mg dose (3 mL of 0.5%) provides sensory blockade lasting 2-5.7 hours depending on spinal level, with motor blockade lasting 1.9-2.7 hours 7

References

Guideline

Bupivacaine Dosage for Epidural Anesthesia

Praxis Medical Insights: Practical Summaries of Clinical Guidelines, 2025

Research

Spinal analgesia with bupivacaine, mepivacaine and tetracaine.

Acta anaesthesiologica Scandinavica, 1983

Guideline

Regional Anesthesia with Ropivacaine and Bupivacaine

Praxis Medical Insights: Practical Summaries of Clinical Guidelines, 2025

Guideline

Dosis de Bupivacaína

Praxis Medical Insights: Practical Summaries of Clinical Guidelines, 2025

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.

Have a follow-up question?

Our Medical A.I. is used by practicing medical doctors at top research institutions around the world. Ask any follow up question and get world-class guideline-backed answers instantly.