What are the immediate steps for a patient with a history of pneumothorax and an implantable cardioverter-defibrillator (ICD) experiencing a device malfunction with the column not moving?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: January 14, 2026View editorial policy

Personalize

Help us tailor your experience

Which best describes you? Your choice helps us use language that's most understandable for you.

Troubleshooting a Non-Functioning Chest Drain in a Pneumothorax Patient with an ICD

When a chest drain (intercostal catheter/ICD) is not showing column movement in a pneumothorax patient, immediately assess for tube obstruction, malposition, or complete lung re-expansion before considering additional interventions—failure to properly troubleshoot can lead to unnecessary procedures or life-threatening complications like tension pneumothorax.

Immediate Assessment Steps

Check for Tube Patency and Function

  • Verify the water seal chamber is bubbling if an air leak is present, or confirm the fluid column oscillates with respiration (tidaling) if the lung has not fully re-expanded 1
  • Inspect the entire drainage system for kinks, dependent loops, or clots that may obstruct flow 2
  • Never clamp a chest tube in a patient with an active air leak or on positive pressure ventilation, as this can rapidly convert a simple pneumothorax into a tension pneumothorax 3
  • Assess tube position by examining the chest radiograph to ensure the tube is properly positioned within the pleural space and all drainage holes are intrathoracic 1

Determine the Cause of Non-Movement

If the column is not moving, consider three primary scenarios:

  1. Complete lung re-expansion with resolved air leak - The most benign cause where the pneumothorax has resolved 1
  2. Tube obstruction - From blood clots, fibrin, or tissue debris blocking the drainage holes or tubing 2
  3. Tube malposition - The tube has migrated out of the pleural space or is positioned against the chest wall 1

Diagnostic Approach

Clinical Examination

  • Assess respiratory status: Look for tachypnea, hypoxia, decreased breath sounds, or hemodynamic instability suggesting tension pneumothorax 2
  • Examine the insertion site: Check for subcutaneous emphysema, tube migration (visible length changes), or signs of infection 1
  • Palpate for subcutaneous air: This may indicate ongoing air leak despite non-functioning drain 1

Radiographic Confirmation

  • Obtain an immediate chest X-ray to assess pneumothorax size, lung expansion, and tube position 1, 2
  • Compare with prior imaging to determine if the pneumothorax is resolving, stable, or enlarging 1

Management Algorithm

If Lung is Fully Re-Expanded and No Air Leak Present

Prepare for tube removal using staged approach:

  • Discontinue suction if applied and observe on water seal for 4-12 hours 1
  • Obtain chest radiograph 5-12 hours after last evidence of air leak to confirm no pneumothorax recurrence 1
  • Remove the tube if radiograph confirms complete resolution and no clinical evidence of air leak 1

If Tube is Obstructed but Pneumothorax Persists

Attempt to restore patency:

  • Gently milk or strip the tubing to dislodge clots, though this is controversial and should be done cautiously 2
  • Flush the tube only if specifically trained and with appropriate protocols, as improper flushing can cause complications 2
  • If obstruction cannot be cleared and pneumothorax is significant, consider inserting a new chest tube rather than persisting with a non-functional one 1, 2

If Tube is Malpositioned

For small pneumothorax in stable patient:

  • Observe with serial chest radiographs if the patient is asymptomatic and pneumothorax is small (<2 cm from chest wall) 1

For large pneumothorax or symptomatic patient:

  • Insert a new chest tube in the appropriate position (typically 4th-5th intercostal space, mid-axillary line) 1
  • Use 16F-22F tube for most cases, or 24F-28F if patient requires positive pressure ventilation or has large air leak 1, 3

Special Considerations for ICD Patients

Device Interrogation Requirements

  • Interrogate the ICD immediately if the patient experiences any hemodynamic instability or arrhythmias during chest tube management 1
  • Be aware that electromagnetic interference from certain medical equipment could affect ICD function during procedures 1
  • Have external defibrillation equipment immediately available throughout the management period 1, 4

Procedural Precautions

  • Position defibrillation pads away from the ICD generator (at least 8 cm) if emergency cardioversion becomes necessary 4
  • Avoid placing the new chest tube on the same side as the ICD if possible to minimize risk of lead damage 5
  • Monitor continuously for device malfunction, as pneumothorax and chest tube placement can rarely cause lead complications 5

Critical Safety Points

Common Pitfalls to Avoid

  • Do not insert additional chest tubes without proper assessment of the existing tube's function and position—this leads to unnecessary procedures and complications 2
  • Do not assume the tube is functioning based solely on its presence; lack of bubbling or tidaling requires investigation 2
  • Do not delay intervention in unstable patients while troubleshooting—if tension pneumothorax is suspected, perform immediate needle decompression followed by definitive tube thoracostomy 3, 2
  • Avoid premature tube removal without confirming complete pneumothorax resolution and cessation of air leak 3

When to Escalate Care

  • Consult respiratory medicine or thoracic surgery if air leak persists beyond 48-72 hours despite functioning chest tube 3
  • Consider chemical pleurodesis (talc or doxycycline) if air leak continues beyond 4 days 3
  • Refer for surgical intervention (VATS or thoracotomy) if conservative management fails or if there is suspected bronchopleural fistula 3, 6

Monitoring Requirements

  • Continuous cardiac monitoring is essential given the ICD and potential for arrhythmias 1
  • Serial chest radiographs every 12-24 hours until pneumothorax resolves 1
  • Document air leak presence and drainage output at regular intervals 1

References

Guideline

Guideline Directed Topic Overview

Dr.Oracle Medical Advisory Board & Editors, 2025

Guideline

Management of Ventilated Patients with Pneumothorax and Suspected Bronchopleural Fistula

Praxis Medical Insights: Practical Summaries of Clinical Guidelines, 2026

Guideline

Using External Defibrillators in Patients with ICDs

Praxis Medical Insights: Practical Summaries of Clinical Guidelines, 2025

Research

Pneumomediastinum and right sided pneumothorax following dual chamber-ICD implantation.

Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 2006

Research

Pneumothorax.

Respirology (Carlton, Vic.), 2004

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.

Have a follow-up question?

Our Medical A.I. is used by practicing medical doctors at top research institutions around the world. Ask any follow up question and get world-class guideline-backed answers instantly.