How should a man with an implanted pacemaker be advised to handle airport security when he is denied entry?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: February 21, 2026View editorial policy

Personalize

Help us tailor your experience

Which best describes you? Your choice helps us use language that's most understandable for you.

Airport Security Management for Pacemaker Patients

The patient should present his pacemaker device identification card to airport security personnel before screening, walk through metal detectors at a normal pace without lingering, and request that hand-held wands be moved quickly over the device area only once. 1

Safe Passage Through Airport Security

Metal Detector Walk-Through Gates

  • Metal detectors at airport security checkpoints do not interfere with cardiac implantable electronic devices (CIEDs) including pacemakers. 1
  • Patients must walk through at normal walking speed and should not stop or linger in the detector archway, as prolonged exposure increases theoretical electromagnetic interference risk. 1
  • A cross-sectional study of 388 patients (209 with pacemakers, 179 with ICDs) demonstrated no device malfunction, pacing inhibition, loss of capture, inappropriate mode switching, or spontaneous reprogramming after 30 seconds of exposure to hand-held metal detectors. 2

Hand-Held Scanner Protocol

  • Hand-held metal detector wands should not affect CIED functionality when used properly. 1
  • Patients should specifically ask security personnel to move the wand over the device quickly and only once, avoiding repetitive scanning over the implant site. 1, 3
  • The electromagnetic flux density of standard hand-held detectors (maximum 6.3 µT) has been proven safe in clinical testing. 2

Full-Body Imaging Scanners

  • Millimeter wave scanners and 3D imaging scanners pose no risk of electromagnetic interference with pacemakers. 1
  • Patients should not linger in these scanners but can pass through them safely. 1

Essential Pre-Travel Preparation

Device Identification Documentation

  • Patients must carry their device identification card at all times and have it ready to show airport personnel before entering the security checkpoint. 1
  • The ACC/AHA/HRS guidelines explicitly state that ICD and pacemaker recipients should be encouraged to carry proper identification and device information at all times. 1

Communication Strategy

  • The patient should proactively inform security personnel about the pacemaker before screening begins. 1
  • If denied entry, the patient should present the device card and request alternative screening methods that comply with the documented safety protocols. 1

Common Pitfall to Avoid

The most critical error is allowing security personnel to repeatedly scan the pacemaker site with a hand-held wand. While a single quick pass is safe, repetitive movement of the detector over the device should be avoided. 1, 3 This misconception often leads to unnecessary anxiety and delays, when in fact the evidence shows these devices are remarkably safe with proper technique. 2

Air Travel Considerations

  • Once through security, electromagnetic interference inside airplanes is rare, though isolated cases have been reported with electronic chair handles. 1
  • Cosmic radiation during flight is approximately 100-fold higher than at ground level, which theoretically increases radiation-induced electromagnetic interference risk (such as power-on reset), but this remains clinically insignificant. 1
  • Magnets are not allowed in carry-on luggage and thus cannot be used to remedy inappropriate device activity during flight. 1

Legal Rights and Recourse

The European Society of Cardiology guidelines emphasize that modern pacing technology permits patients to lead normal active lives, including travel. 1 If airport personnel deny entry despite proper documentation and willingness to follow safety protocols, the patient should request to speak with a supervisor and reference the established medical guidelines demonstrating the safety of standard security screening procedures for pacemaker patients. 1, 2

References

Guideline

Guideline Directed Topic Overview

Dr.Oracle Medical Advisory Board & Editors, 2025

Research

[Travelling with a pacemaker or implanted defibrillator].

Herzschrittmachertherapie & Elektrophysiologie, 2019

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.