Management of Intra-Atrial Shunt on Echocardiogram
For adults with an intra-atrial shunt identified on echocardiography, immediately distinguish between patent foramen ovale (PFO) and atrial septal defect (ASD) using transthoracic echocardiography with bubble study, then proceed to closure (transcatheter for secundum ASD, surgical for other types) if there is right ventricular enlargement with Qp:Qs ≥1.5:1 and pulmonary artery systolic pressure <50% of systemic pressure. 1
Initial Diagnostic Evaluation
Distinguish PFO from ASD
- Transthoracic echocardiography (TTE) with saline contrast ("bubble study") is the first-line diagnostic test to identify the shunt and assess right ventricular volume overload 1
- Look for fixed splitting of the second heart sound and a systolic pulmonary flow murmur on physical examination, which suggest ASD rather than PFO 1
- Right ventricular volume overload is the key finding that distinguishes hemodynamically significant ASD from incidental PFO—this is more important than the shunt ratio alone 1
- PFO typically shows minimal or no right heart enlargement, while ASD causes progressive right atrial and RV dilation 1
Advanced Imaging When Needed
- Transesophageal echocardiography (TEE) is required for precise evaluation before device closure, including defect sizing, rim assessment (need ≥5mm except toward aorta), exclusion of additional defects, and confirmation of normal pulmonary venous connections 1
- TEE is particularly necessary for sinus venosus defects, which are difficult to visualize on TTE 1
- Cardiac MRI or CT can serve as alternatives if echocardiography is insufficient, particularly for assessing RV volume overload and pulmonary venous anatomy 1
Hemodynamic Assessment
Key Measurements Required
- Measure Qp:Qs ratio (pulmonary-to-systemic blood flow ratio) using echocardiography—a ratio ≥1.5:1 indicates hemodynamically significant shunting 1
- Estimate pulmonary artery systolic pressure relative to systemic pressure using tricuspid regurgitation velocity 1
- Assess right heart chamber sizes—right atrial and/or RV enlargement indicates volume overload requiring intervention 1
When Cardiac Catheterization Is Required
- Perform right heart catheterization if PA systolic pressure appears ≥50% of systemic pressure on echo, if pulmonary vascular resistance may be elevated, or if the patient is >40 years old 1, 2, 3
- Catheterization is not routinely needed in younger patients with clear TTE/TEE findings showing normal PA pressures and obvious RV volume overload 2, 3
- Older adults (>40 years) frequently have acquired left ventricular diastolic dysfunction that can paradoxically worsen after ASD closure, making pre-closure catheterization essential in this population 2, 3
Management Algorithm by Defect Type and Hemodynamics
Secundum ASD with Favorable Hemodynamics (Class I Indication)
Proceed with transcatheter or surgical closure if: 1
- Qp:Qs ≥1.5:1 with RV enlargement
- PA systolic pressure <50% of systemic pressure
- Pulmonary vascular resistance <1/3 systemic resistance
- Symptomatic (impaired functional capacity) OR asymptomatic with clear RV volume overload
Device closure is preferred for secundum ASD when anatomically suitable (stretched diameter <38mm, adequate rim ≥5mm except toward aorta) 1
Non-Secundum ASDs (Primum, Sinus Venosus, Coronary Sinus)
Surgical repair is required for these defects when hemodynamically significant (same criteria as above), as they are not amenable to percutaneous device closure 1
Borderline Pulmonary Pressures (Class IIb)
Closure may be considered when: 1
- Qp:Qs ≥1.5:1 AND
- PA systolic pressure is 50-67% of systemic pressure OR
- Pulmonary vascular resistance is 1/3 to 2/3 of systemic resistance
This requires expert consultation and often a trial of pulmonary vasodilator therapy with reassessment 1
Absolute Contraindications to Closure (Class III)
Do not close the defect if: 1, 4
- PA systolic pressure >2/3 systemic pressure
- Pulmonary vascular resistance >2/3 systemic resistance
- Net right-to-left shunt present (Eisenmenger physiology)
Closure in these patients causes acute right ventricular failure and is fatal 4
Patent Foramen Ovale Management
PFO with Cryptogenic Stroke
Device closure plus antiplatelet therapy is recommended over antiplatelet therapy alone for secondary stroke prevention in carefully selected patients with cryptogenic stroke and PFO 1
- Transesophageal echocardiography with bubble study and Valsalva maneuver increases sensitivity for PFO detection 1
- Look for atrial septal aneurysm (excessive bulging of fossa ovalis), which may indicate increased embolic risk 1
- Antiplatelet therapy (aspirin 100mg daily minimum) is required for at least 6 months after device closure 1
Incidental PFO Without Symptoms
Observation is appropriate for incidental PFO without history of paradoxical embolism, cryptogenic stroke, or significant right-to-left shunting 1
Post-Closure Management
Immediate Post-Procedure
- Antiplatelet therapy for minimum 6 months (aspirin 100mg daily) after device closure 1
- Echocardiography before hospital discharge to assess for residual shunt, device position, and pericardial effusion 1
- Monitor for early atrial arrhythmias, which are usually transient 1
Long-Term Follow-Up
- Annual follow-up at an adult congenital heart disease center for patients with residual shunt, pulmonary hypertension, or RV dysfunction 1
- Patients repaired before age 25 with no residual defects, normal PA pressure, normal RV, and no arrhythmias do not require regular follow-up 1
- Every 3-5 years for small residual defects without other complications 1
Critical Pitfalls to Avoid
- Do not assume all intra-atrial shunts are benign—unoperated ASDs carry 25% mortality before age 27 and 90% mortality by age 60 4
- Never close an ASD with established severe pulmonary vascular disease (PA pressure >2/3 systemic or PVR >2/3 systemic)—this is uniformly fatal 1, 4
- Do not skip hemodynamic assessment in patients >40 years old—they often have diastolic dysfunction that worsens after closure 2, 3
- Distinguish between secundum and non-secundum defects early—only secundum defects are suitable for percutaneous closure 1
- If a patient with known left-to-right ASD develops cyanosis, immediately assess for shunt reversal (Eisenmenger syndrome) or bidirectional shunting before any intervention 4, 5