Ankle-Brachial Index: Measurement, Interpretation, and Management
The ankle-brachial index (ABI) should be measured using a handheld Doppler device with the higher of the dorsalis pedis or posterior tibial artery pressure divided by the higher brachial artery pressure, with an ABI <0.90 confirming peripheral arterial disease (PAD) and values <0.90 or >1.40 indicating significantly increased cardiovascular risk. 1
How to Measure the ABI
Equipment and Technique
- Use a handheld Doppler device with appropriate gel applied over the sensor
- Position the probe at 45° to 60° angle to the skin surface
- Move the probe until the clearest signal is heard 1
Measurement Sequence
Follow this specific order consistently 1:
- First arm (brachial)
- First leg posterior tibial (PT) artery
- First leg dorsalis pedis (DP) artery
- Second leg PT artery
- Second leg DP artery
- Second arm (brachial)
- Repeat the first arm measurement
Blood Pressure Measurement Protocol
- Inflate the cuff progressively to 20 mm Hg above flow signal disappearance
- Maximum inflation is 300 mm Hg
- Deflate slowly to detect pressure at flow signal reappearance 1
Critical Measurement Rule
If the difference between the two first arm measurements exceeds 10 mm Hg, discard the first measurement and use only the second measurement 1. Otherwise, average the two first arm measurements to account for white coat effect.
How to Calculate the ABI
The Calculation Formula
ABI = Higher ankle pressure (PT or DP) ÷ Higher brachial pressure (left or right arm) 2
Which Ankle Pressure to Use: A Critical Decision
For diagnostic purposes (confirming suspected PAD): Use the higher of the PT or DP pressures at each ankle 1
- This provides higher specificity (99% vs 93%)
- Minimizes overdiagnosis and unnecessary testing
- Prevents false positives in healthy subjects
For cardiovascular risk stratification: Use the lower of the PT or DP pressures 1, 3
- Identifies more patients at cardiovascular risk
- Better captures unilateral or asymmetric disease
- The lower ABI identifies individuals who would be missed using the higher value
Important caveat: If one ankle artery signal is absent but the other ankle artery shows normal ABI, perform duplex ultrasound to rule out PAD 1
Interpretation of ABI Values
Diagnostic Thresholds 1
| ABI Value | Interpretation | Action Required |
|---|---|---|
| <0.90 | PAD confirmed | Diagnose PAD; assess cardiovascular risk |
| 0.91-1.00 | Borderline | Further evaluation appropriate; consider exercise ABI |
| 1.00-1.40 | Normal | No PAD |
| >1.40 | Non-compressible vessels | Use toe-brachial index (TBI) or other tests |
When ABI is Unreliable
ABI >1.40 indicates vessel calcification (common in diabetes and chronic kidney disease), making the test unreliable 2. In these cases:
- Obtain toe-brachial index (TBI) with waveforms
- Normal TBI is >0.70 2
- Consider transcutaneous oxygen pressure (TcPO2) or skin perfusion pressure (SPP)
Exercise ABI Testing
Indications 1
Perform exercise ABI when:
- Resting ABI is >0.90 but clinical suspicion for PAD remains high
- Patient has exertional leg symptoms suggestive of claudication
Diagnostic Criteria for Abnormal Exercise ABI 1
- Post-exercise ankle pressure decrease >30 mm Hg, OR
- Post-exercise ABI decrease >20%
Management Based on ABI Results
For Asymptomatic Patients with Abnormal ABI
ABI <0.90 or >1.40 = High cardiovascular risk 1
- Hazard ratio for cardiovascular mortality: 4.2 in men, 3.5 in women 1
- Initiate aggressive cardiovascular risk factor modification
- Consider these patients equivalent to coronary artery disease patients for risk stratification
For Symptomatic Patients
ABI <0.90 with symptoms: 1
- Confirm PAD diagnosis
- If symptoms are functionally limiting, obtain anatomic imaging (duplex ultrasound, CTA, MRA, or catheter angiography) to plan revascularization 2
- Initiate guideline-directed medical therapy and structured exercise program
ABI >0.90 with persistent symptoms:
- Perform exercise ABI testing
- If exercise ABI is abnormal, proceed with anatomic imaging
- If exercise ABI is normal, seek alternative diagnosis 2
Common Pitfalls and How to Avoid Them
Measurement Errors
Problem: Studies show ABI is often incorrectly performed in primary care, with great variability compared to vascular laboratory measurements 4
Solutions:
- Use standardized technique consistently
- Ensure proper training for personnel performing the test 1
- When ABI values are close to threshold (0.80-1.00), consider repeating or referring to vascular laboratory
Automated Devices
Automated oscillometric devices have poor concordance with Doppler 5
- Sensitivity as low as 8-33% compared to Doppler
- Do not use automated devices for PAD screening in primary care
- Stick with handheld Doppler as the standard 5
Reproducibility Concerns
Reproducibility is only crucial when ABI is near threshold values 1
- With 95% CI of ±0.10, an ABI ≤0.80 is definitively abnormal
- An ABI ≥1.00 is definitively normal
- Values between 0.80-1.00 may warrant repeat measurement
Cardiovascular Risk Prediction
The ABI provides incremental prognostic information beyond traditional risk scores 1. For every patient with ABI <0.90:
- Intensify cardiovascular risk factor management
- Screen for coronary and carotid artery disease
- Consider as high-risk for cardiovascular events regardless of symptoms
The ABI remains one of the most cost-effective tests providing both diagnostic accuracy for PAD and robust prognostic information for cardiovascular events 6, 7.