What is the acceptable discrepancy when measuring height?

Medical Advisory BoardAll articles are reviewed for accuracy by our Medical Advisory Board
Educational purpose only • Exercise caution as content is pending human review
Article Review Status
Submitted
Under Review
Approved

Last updated: May 9, 2025View editorial policy

Personalize

Help us tailor your experience

Which best describes you? Your choice helps us use language that's most understandable for you.

From the Guidelines

When measuring height, a discrepancy of up to 0.4 cm is considered acceptable, as indicated by the need to check if two measurements are within this range of each other 1. This guideline ensures consistency and accuracy in height measurements, which is crucial for various medical assessments and calculations.

  • The acceptable discrepancy is based on the protocol for taking skinfold measurements, which emphasizes the importance of precise and consistent measurements.
  • To achieve accurate height measurements, it is essential to use proper technique, including having the person stand straight with heels against the wall and looking straight ahead with shoulders relaxed.
  • Multiple measurements may be taken and averaged for greater accuracy, especially if the initial measurements are not within the acceptable range of 0.4 cm of each other 1.
  • Larger discrepancies beyond 0.4 cm might indicate measurement error or, if consistent across different measurement sessions, could potentially signal medical concerns that might warrant further investigation.
  • The use of standardized equipment, such as stadiometers, can also help minimize discrepancies and ensure accurate height measurements.

From the Research

Discrepancy in Height Measurements

  • The acceptable discrepancy in height measurements is not explicitly stated, but studies have reported variations in measurements using different techniques and tools.
  • A study published in 2016 2 found that the technical error of measurement (TEM) for clinical height measurements was 1.77 cm, with a relative TEM of 1.04%.
  • Another study from 2000 3 demonstrated that the "in place" method of stadiometry reduced random variation due to posture change, resulting in more reliable measurements.
  • The validity and reliability of tape measurement methods for leg length discrepancy were reviewed in a 2019 study 4, which found high to very high levels of interrater and intrarater reliability, but limited validity in certain populations.

Factors Affecting Height Measurements

  • Posture change and movement during measurement can introduce variability, as shown in a 2000 study 3 that compared "in-out" and "in place" methods of stadiometry.
  • The use of different measurement tools, such as stadiometers, can also affect results, as demonstrated in a 2016 study 5 that evaluated the reliability of a custom-built seated stadiometry set-up.
  • A 2009 study 6 investigated the effects of sustained lumbar flexion and extension postures on spinal height, finding significant increases in height after both supine flexion and prone extension lying.

Measurement Techniques and Tools

  • Stadiometry is a common method for measuring spinal height, and its reliability has been evaluated in several studies, including those published in 2009 6 and 2016 5.
  • Tape measurement methods have also been reviewed, with a 2019 study 4 finding acceptable reliability and validity in healthy populations, but limited validity in obese individuals and those with musculoskeletal disorders.
  • The use of electronic health records (EHRs) for height measurements has been shown to be unreliable, with a 2016 study 2 finding that 18% of patients had height measurement differences of ≥2 cm over a 3-month period.

References

Guideline

Guideline Directed Topic Overview

Dr.Oracle Medical Advisory Board & Editors, 2025

Research

Clinical height measurements are unreliable: a call for improvement.

Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA, 2016

Professional Medical Disclaimer

This information is intended for healthcare professionals. Any medical decision-making should rely on clinical judgment and independently verified information. The content provided herein does not replace professional discretion and should be considered supplementary to established clinical guidelines. Healthcare providers should verify all information against primary literature and current practice standards before application in patient care. Dr.Oracle assumes no liability for clinical decisions based on this content.