How to Perform Double Eversion of the Upper Eyelid
Double eversion of the upper eyelid is performed by first everting the lid in standard fashion, then re-everting the already-everted tarsal conjunctiva to expose the superior fornix and its contents.
Technique
Standard (Single) Eversion - First Step
- Ask the patient to look down while keeping both eyes open
- Grasp the eyelashes at the central portion of the upper lid between your thumb and index finger
- Pull the lid gently downward and outward to disengage it from the globe
- Place your other thumb or index finger (or a cotton-tipped applicator) on the skin overlying the superior border of the tarsal plate (approximately 10mm above the lid margin)
- Apply gentle downward pressure with the finger/applicator while simultaneously pulling the lashes upward and over your pressing digit
- The lid will evert, exposing the tarsal conjunctiva 1
Double Eversion - Second Step
Once the lid is everted in standard fashion:
- Maintain the first eversion by holding the everted lid margin
- Apply additional upward traction on the already-everted lid margin
- Use your other hand to apply pressure at the superior edge of the now-visible tarsus
- Push upward and posteriorly to fold the tarsal conjunctiva back upon itself
- This exposes the superior fornix, allowing visualization of material that may be hidden in the deep fornix (such as the mucopurulent coagulum seen in giant fornix syndrome) 2
Clinical Context and Indications
Double eversion is particularly valuable for:
- Giant fornix syndrome: Reveals enlarged superior fornix with coagulum of mucopurulent material in elderly patients 2
- Floppy eyelid syndrome: Demonstrates the easily everted upper lid with diffuse papillary reaction 2, 3
- Foreign body detection: Exposes material lodged deep in the superior fornix
- Giant papillary conjunctivitis: Better visualization of superior tarsal papillary hypertrophy 2
Key Technical Points
Comfort optimization: Using your finger alone or a silicone everter at the top of the tarsal plate provides the most comfortable technique while exposing the greatest area 1. The wooden end of cotton-tipped applicators or off-center placement causes more discomfort and should be avoided.
Patient positioning: Have the patient look downward throughout the procedure to relax the levator muscle and facilitate eversion.
Gentle technique: Excessive force or repeated manipulation can cause mechanical irritation. The procedure should be smooth and deliberate 4.
Common Pitfalls
- Inadequate initial eversion: If the first eversion is incomplete, the second eversion will be impossible
- Patient looking up: This tenses the levator and prevents proper eversion
- Excessive force: Can cause corneal abrasion or patient discomfort
- Inadequate superior fornix exposure: Failing to push far enough posteriorly during the second eversion misses the diagnostic benefit
The technique is reproducible with consistent results when performed correctly 1.